English
Language : 

DRC3P48D400R2 Datasheet, PDF (1/12 Pages) Crydom Inc., – DRC Series
DataDINsRhaileMeoutnt
DRC Series
• 7.6 Amp AC Semiconductor Motor Controller
• Load voltage range up to 600 VAC
• Fits standard 35mm DIN Rail
• LED input status indicator
• AC or DC control
• Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
• C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
• Built-in Overvoltage Protection
• Ultra-efficient thermal management design (Patented)
Start / Stop Reversing
Solicon DRC3 Series are Solid State Contactors intended for
frequently switching on and off three phase loads up to 5 HP, 600
VAC 7.6 Amps. They are available in both contactor versions
DRC3P and reversing contactor versions DRC3R.
The Solicon Contactor DRC3P is available in either instantaneous
turn-on (for Motor Control) or zero voltage turn-on (for Resistive
Loads). It is available in either 2 or 3 controlled leg versions. The
2 legs control version is particularly suitable for motor control
circuits where the neutral conductor is not utilized.
The Solicon Reversing Contactor DRC3R includes an interlock
control that allows only off, forward and reverse operation in a
safe mode while providing high space saving; it switches
instantaneously upon application of the control voltage unless an
instantaneous change of direction is commanded, then it will
delay the direction change by 100msec in order to prevent
simultaneous forward and reverse operations.
All the models of Solicon DRC3 Series combine the benefits and
advantages of a solid state contactor with the functionality and
simplicity of use of an electromechanical contactor thanks to the
proprietary thermal management technology (Patented) and
complete electrical insulation (no grounding required); the
embedded auxiliary contacts, normally open and/or normally
closed, are intended to be used at 18-280VAC. Five different
control voltages are available in order to cover most applications.
All models include overvoltage protection.
PRODUCT SELECTION
Control Voltage
230 VAC
120 VAC
48 VAC/DC
24 VAC/DC, 24 VAC
24 VDC
Without Auxiliary Contact
DRC3P48A400, DRC3R48A400
DRC3P48B400, DRC3R48B400
DRC3P48C400, DRC3R48C400
DRC3P48D400, DRC3R48D400
DRC3R48E400
1 NO+NC Auxiliary Conctat
DRC3P48A411
DRC3P48B411
DRC3P48C411
DRC3P48D411
2 NO Auxiliary Contact
DRC3P48A420, DRC3R48A420
DRC3P48B420, DRC3R48B420
DRC3P48C420, DRC3R48C420
DRC3P48D420, DRC3R48D420
DRC3R48E420
AVAILABLE OPTIONS
Series
Operating Voltage
40: 400 VAC
(3R function only)
48: 480 VAC
60: 600 VAC
(3P function only)
Load Current per Phase
4: 7.6 Amp FLA
(x2 Controlled Legs
& 3R function);
4.8 Amp FLA
(x3 Controlled Legs only)
Switching Mode
(3P function only)
Blank: Zero Voltage Turn-On
R: Instantaneous Turn-On
DRC 3P 48 D 4 00 R 2
Function
3P: Contactor
3R: Reversing Contactor
Required for valid part number
For options only and not required for valid part number
Control Voltage
A: 208-265 VAC
B: 90-140 VAC
C: 36-55 VAC/DC
D: 18-30 VAC/DC
(3P function only)
18-30 VAC
(3R function only)
E: 18-30 VDC
(3R function only)
Auxiliary Contacts,
Controlled Legs
N.O. - N.C.
(3P function only)
00: Not included
Blank: 3 Controlled Legs
11: 1 Solid State Auxiliary 2: 2 Controlled Legs
Contact, Normally Open;
1 Solid State Auxiliary
Contact, Normally Closed
(3P function only)
20: 2 Solid State Auxiliary
Contacts, Normally Open
FDE-07-01 REV. A
Do not forget to visit us at: www.crydom.com