English
Language : 

XQ-E Datasheet, PDF (4/31 Pages) Cree, Inc – Cree XLamp XQ-E LEDs
XLamp® XQ-E LED
Flux Characteristics - High Density Color (TJ = 25 °C)
The following tables provide several base order codes for XLamp XQ-E High Density color LEDs. It is important to note that the base
order codes listed here are a subset of the total available order codes for the product family. For more order codes, as well as a complete
description of the order-code nomenclature, please consult the XLamp XQ Family LEDs Binning and Labeling document.
Color
Royal
Blue
Dominant Wavelength Range
Minimum
Group
DWL
(nm)
Maximum
Group
DWL
(nm)
D36
450
D57
465
Minimum Radiant Flux
(mW) @ 350 mA
Group Flux (mW)
36 (Q)
600
35 (P)
575
34 (N)
550
33 (M)
525
32 (L)
500
31 (K)
475
30 (J)
450
Order Code
XQEROY-00-0000-000000Q01
XQEROY-00-0000-000000P01
XQEROY-00-0000-000000N01
XQEROY-00-0000-000000M01
XQEROY-00-0000-000000L01
XQEROY-00-0000-000000K01
XQEROY-00-0000-000000J01
Color
Blue
Dominant Wavelength Range
Minimum
Maximum
Group
DWL
(nm)
Group
DWL
(nm)
B3
465
B6
485
Minimum Luminous
Flux (lm) @ 350 mA
Group
M3
M2
K3
K2
Flux (lm)
45.7
39.8
35.2
30.6
Order Code
XQEBLU-00-0000-000000301
XQEBLU-00-0000-000000201
XQEBLU-00-0000-000000Z01
XQEBLU-00-0000-000000Y01
Color
Dominant Wavelength Range
Minimum
Group
DWL
(nm)
Maximum
Group
DWL
(nm)
Green
G2
520
G4
535
Minimum Luminous
Flux (lm) @ 350 mA
Group
Q5
Q4
Q3
Flux (lm)
107
100
93.9
Order Code
XQEGRN-00-0000-000000D01
XQEGRN-00-0000-000000C01
XQEGRN-00-0000-000000B01
Note
• Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and a
tolerance of ±2 on CRI measurements. See the Measurements section (page 25).
Copyright © 2013-2016 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree® and XLamp® are registered trademarks and the Cree logo is a trademark of
Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
4