English
Language : 

FMSA-461 Datasheet, PDF (6/6 Pages) Interpoint Corporation Company – EMI INPUT FILTER 28 VOLT INPUT
FMSA EMI FILTER EMI INPUT FILTERS
0.8 AMP
QA SCREENING
125°C PRODUCTS
TEST (125°C Products)
125°C PRODUCTS
125°C
STANDARD
125°C
/ES
/883 (Class H)*
Pre-cap Inspection
Method 2017, 2032
yes
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
no
no
yes
Method 1010, Cond. B, -55°C to 125°C, ambient
no
yes
no
Constant Acceleration
Method 2001, 300 g
Method 2001, 500g
no
no
yes
no
yes
no
Burn-In
Method 1015, 160 hours at 125°C case, typical
no
no
yes
96 hours at 125°C case, typical
no
yes
no
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C case
no
no
yes
Subgroups 1 and 4: +25°C case
yes
yes
no
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10-3)
no
yes
yes
no
yes
yes
yes
no
no
Final Visual Inspection
Method 2009
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
*883 products are built with element evaluated components and are 100% tested and guaranteed over
the full military temperature range of –55°C to +125°C.
FMSA Rev B 20050522
All technical information is believed to be accurate, but no responsibility is
assumed for errors or omissions. Interpoint reserves the right to make changes in
®
6
products or specifications without notice. FMSA Series is a trademark of