English
Language : 

CPC7583_1 Datasheet, PDF (9/21 Pages) Clare, Inc. – Line Card Access Switch
1.6.5 Ringing Test Return Switch, SW7
Parameter
Test Conditions
Off-state leakage current
+25° C
VSW (differential) = -320 V to gnd
VSW (differential) = +260 to -60 V
+85° C
VSW (differential) = -330 V to gnd
VSW (differential) = +270 V to -60 V
-40° C
VSW (differential) = -310 V to gnd
VSW (differential) = +250 V to -60 V
RON
+25° C
+85° C
-40° C
ISW(on) = ±10 mA, ±40 mA
DC current limit
+25° C
+85° C
-40° C
VSW (on) = ±10 V
Logic input to switch output isolation
+25° C
VSW (TRING, TTESTin) = ±320 V, logic
inputs = gnd
+85° C
VSW (TRING, TTESTin) = ±330 V, logic
inputs = gnd
-40° C
VSW (TRING, TTESTin) = ±310 V, logic
inputs = gnd
dv/dt sensitivity
-
CPC7583
Symbol Minimum Typical Maximum
Unit
0.1
ISW
-
0.3
1
μA
0.1
RON
-
60
-
85
100
Ω
45
-
120
ISW
70
80
-
mA
210
0.1
ISW
-
0.3
1
μA
0.1
-
200
-
V/μs
R06
www.clare.com
9