English
Language : 

CPC7591 Datasheet, PDF (6/19 Pages) Clare, Inc. – Line Card Access Switch
CPC7591
1.6.2 Ringing Return Switch, SW3
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW3 (differential) = TLINE to TRINGING
All-Off state.
+25° C,
VSW (differential) = -320 V to gnd
0.1
VSW (differential) = +260 V to -60 V
Off-State
Leakage Current
+85° C,
VSW (differential) = -330 V to gnd
ISW
-
0.3
1
μA
VSW (differential) = +270 V to -60 V
-40° C,
VSW (differential) = -310 V to gnd
0.1
VSW (differential) = +250 V to -60 V
ISW(on) = ±0 mA, ±10 mA
On Resistance
+25° C
+85° C
-40° C
RON
-
60
-
85
100
Ω
45
-
VSW (on) = ± 10 V
DC current limit
+25° C
+85° C
-40° C
-
135
ISW
70
85
-
mA
-
210
Dynamic current limit
(t ≤ 0.5 μs)
Ringing switches on, all other switches
off. Apply ±1 kV 10x1000 μs pulse with
appropriate protection in place.
ISW
-
2.5
-
A
Logic inputs = GND
Logic input to switch +25° C, VSW (TRINGING, TLINE) = ±320V
0.1
output isolation
+85° C, VSW (TRINGING, TLINE) = ±330V
ISW
-
0.3
1
μA
-40° C, VSW (TRINGING, TLINE) = ±310 V
0.1
dv/dt sensitivity
100VPP Square Wave, 100Hz
(Not production tested - limits are
-
guaranteed by design and quality
control sampling audits.)
-
500
-
V/μs
6
www.clare.com
R05