English
Language : 

CPC7592 Datasheet, PDF (3/20 Pages) Clare, Inc. – Line Card Access Switch
1. Specifications
1.1 Package Pinout
FGND 1
TBAT 2
TLINE 3
TRINGING 4
TTEST 5
VDD 6
CPC7592
16 VBAT
15 RBAT
14 RLINE
13 RRINGING
12 RTEST
11 LATCH
TSD 7
DGND 8
10 INRINGING
9 INTEST
1.2 Pinout
Pin Name
Description
1
FGND Fault ground
2
TBAT Tip lead to the SLIC
3
TLINE Tip lead of the line side
4 TRINGING Ringing generator return
5
TTEST Tip lead of the test bus
6
VDD +5 V supply
7
TSD Temperature shutdown pin
8
DGND Digital ground
9
INTEST Logic control input
10 INRINGING Logic control input
11 LATCH Data latch enable control input
12
RTEST Ring lead of the test bus
13 RRINGING Ringing generator source
14
RLINE Ring lead of the line side
15
RBAT Ring lead to the SLIC
16
VBAT Battery supply
CPC7592
1.3 Absolute Maximum Ratings
Parameter
Minimum Maximum Unit
+5 V power supply (VDD)
-0.3
7
V
Battery Supply
-
-85
V
DGND to FGND Separation
-5
+5
V
Logic input voltage
-0.3 VDD + 0.3 V
Logic input to switch output
isolation
-
320
V
Switch open-contact
isolation (SW1, SW2, SW3, -
320
V
SW5, SW6)
Switch open-contact
Isolation (SW4)
-
465
V
Operating relative humidity
5
95
%
Operating temperature
-40
+110
°C
Storage temperature
-40
+150
°C
Absolute maximum electrical ratings are at 25°C.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.4 ESD Rating
ESD Rating (Human Body Model)
1000 V
1.5 General Conditions
Unless otherwise specified, minimum and maximum
values are production testing requirements. Typical
values are characteristic of the device and are the
result of engineering evaluations. They are provided
for information purposes only and are not part of the
testing requirements.
Specifications cover the operating temperature range
TA = -40° C to +85° C. Also, unless otherwise specified
all testing is performed with VDD = 5Vdc, logic low input
voltage is 0Vdc and logic high voltage is 5Vdc.
R03
www.clare.com
3