English
Language : 

LCA182 Datasheet, PDF (2/5 Pages) Clare, Inc. – Single Pole OptoMOS Relay
LCA182
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Blocking Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Ratings
1501
50
1
5
350
8002
3750
-40 to +85
-40 to +125
+260
-+220
Units
mW
mA
A
V
V
mW
VRMS
°C
°C
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Conditions
Symbol Min Typ
Output Characteristics @ 25°C
Load Current (Continuous)
AC/DC Configuration
DC Configuration
Peak Load Current
On-Resistance
-
-
10ms
I
-
-
L
I
-
-
L
ILPK
-
-
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
IL=120mA
I =200mA
L
VL=350V
RON
R
ON
ILEAK
-
23
-
7
-
-
Turn-On
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
IF=1mA, VL=10V
I =1mA, V =10V
F
L
50V; f=1MHz
TON
T
OFF
C
OUT
-
-
-
-
25
Input Control Current1
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
I =120mA
L
-
IF=1mA
V =5V
R
I
0.25
-
F
I
0.05
-
F
VF
0.9 1.2
I
-
-
R
Input to Output Capacitance
-
CI/O
-
3
1 It is recommended that the input control current be increased to 1mA in high temperature (over+55oC) operation.
Max Units
120 mA
200 mA
350 mA
35
Ω
10
Ω
1
µA
3
ms
3
ms
-
pF
-
mA
-
mA
1.4
V
10
µA
-
pF
2
www.clare.com
R01.1