English
Language : 

CPC7583 Datasheet, PDF (2/16 Pages) Clare, Inc. – Line Card Access Switch
CPC7583
Parameter
Min
Operating Temperature Range
-40
Storage Temperature Range
-40
Relative Humidity Range
5
Pin Soldering Temperature
-
(t=10 s max)
+5V Power Supply
-
Battery Supply
-
Logic Input Voltage
-
Logic Input to Switch Output Isolation -
Switch Isolation (SW1, SW2, SW3,
-
SW5, SW6, SW7, SW9,SW10)
Switch Isolation (SW4)
-
Switch Isolation (SW8)
-
Max
+110
+150
95
+260
Units
˚C
˚C
%
˚C
7
V
-85
V
7
V
330
V
330
V
480
V
235
V
Absolute Maximum Ratings are stress ratings. Functional op-
eration of the device at these or any other conditions beyond
those indicated in the operational sections of this data sheet is
not implied. Exposure of the device to the absolute maximum
ratings for extended period may degrade the device and effect
its reliability.
Electrical Characteristics TA = -40oC to +85oC (unless otherwise specified)
Minimum and maximum values are production testing requirements. Typical values are characteristic of the device and are the result
of engineering evaluations. Typical values are provided for information purposes only and are not part of the testing requirements.
Power Supply Specifications
Supply
Min
Typ Max
Unit
ESD Rating (HBM Model)
VDD
+4.5 +5.0 +5.5
V
V1
-19
-
-72
V
BAT
1000
1 VBAT is used only as a reference for internal protection circuitry.
If VBAT rises above -10V, the device will enter an all off state and will remain in the all off state until the battery voltage drops below -15V.
Table 1. Break Switch, SW1 and SW2
PARAMETERS
CONDITIONS
SYMBOL
MIN
TYP
Off-state Leakage Current:
+25oC
Vsw (differential)= -320V to Gnd
Isw
-
0.1
+85oC
Vsw (differential)= -60V to +260V
Vsw (differential)= -330V to Gnd
Isw
-
0.3
-40oC
Vsw (differential)= -60V to +270V
Vsw (differential)= -310V to Gnd
Isw
-
0.1
Vsw (differential)= -60V to +250V
RDSON (SW1,SW2):
+25oC
TLINE= +/-10 mA, +/-40mA, TBAT= -2V
∆V
+85oC
TLINE= +/-10 mA, +/-40mA, TBAT= -2V
∆V
-40oC
TLINE= +/-10 mA, +/-40mA, TBAT= -2V
∆V
-
14.5
-
20.5
-
10.5
RDSON Match
Per ON-resistance Test Condition of
Magnitude
-
0.15
SW1, SW2
RON SW1-RONSW2
DC Current Limit:
+25oC
Vsw (on) = +/- 10V
Isw
-
225
+85oC
Vsw (on) = +/- 10V
Isw
80
150
-40oC
Vsw (on) = +/- 10V
Isw
-
400
Dynamic Current Limit: Break switches in ON state, ringing
Isw
-
2.5
(t=<0.5µs)
access switches OFF, apply +/- 1000V
at 10/1000µs pulse, appropriate
secondary protection in place.
Logic Input to Switch Output Isolation:
+25oC
Vsw (TLINE, RLINE) = +/-320V
Logic Inputs = Gnd
+85oC
Vsw (TLINE, RLINE) = +/-330V
Logic Inputs = Gnd
-40oC
Vsw (TLINE, RLINE) = +/-310V
Logic Inputs = Gnd
Isw
-
0.1
Isw
-
0.3
Isw
-
0.1
dv/dt Sensitivity1
-
-
-
200
1 Applied voltage is 100 Vp-p square wave at 100Hz.
2
www.clare.com
MAX
UNITS
1
µA
1
µA
1
µA
-
Ω
28
Ω
-
Ω
0.8
Ω
-
mA
-
mA
425
mA
-
A
1
µA
1
µA
1
µA
-
V/µs
Rev. E