English
Language : 

CPC1909 Datasheet, PDF (2/6 Pages) Clare, Inc. – ISOPLUS™-264 Power Relay
CPC1909
Absolute Maximum Ratings
Parameter
Ratings
Blocking Voltage
60
Reverse Input Voltage
5
Input Control Current
100
Peak (10ms)
1
Units
VP
V
mA
A
Input Power Dissipation
150
mW
Isolation voltage Input to Output
2500
Vrms
Operational Temperature
-40 to +85
°C
Storage Temperature
-40 to +125
°C
Electrical absolute maximum ratings are at 25°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Output Characteristics,
Load Current 1
TA = 25°C
Peak
Continuous
Continuous
Continuous
On-Resistance 2
Off-State Leakage Current
Switching Speeds
t ≤ 10ms
No Heat Sink
IL
-
TC=25°C
TC=99°C
IL(99)
IF=10mA, IL=1A
RON
-
VL=60V
ILEAK
-
Turn-On
Turn-Off
IF=20mA, VL=10V
TON
TOFF
-
-
Output Capacitance
V=25V, f=1MHz
COUT
-
Input Characteristics,
TA = 25°C
Input Control Current 3
IL=1A
IF
-
Input Dropout Current
-
IF
0.6
Input Voltage Drop
IF=5mA
VF
0.9
Reverse Input Current
VR=5V
IR
-
Common Characteristics,
TA = 25°C
Capacitance Input to Output
-
CI/O
-
1 Proper heat sinking required for maximum continuous load current.
2 Measurement taken within 1 second of on time.
3 For applications requiring high temperature operation (TC > 60°C) an LED drive current of 20mA is recommended.
Typ
-
0.05
-
15
0.3
4000
-
-
1.2
-
1
Max Units
25
AP
6.5
15
Arms
7.85
0.1
Ω
1
µA
25
ms
10
-
pF
10
mA
-
mA
1.4
V
10
µA
-
pF
2
www.clare.com
R03