Absolute Maximum Ratings
Parameter
Blocking Voltage
Reverse Input Voltage
Input control Current
Peak (10ms)
Input Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Ratings
600
5
50
1
150
2500
-40 to +85
-40 to +125
Units
VP
V
mA
A
mW
Vrms
°C
°C
Electrical absolute maximum ratings are at 25°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Output Characteristics
Load Current 1
TA=25°C
Peak
t ≤ 10ms
Continuous
Continuous
Continuous
On-Resistance 2
Off-State Leakage Current
Switching Speeds
No Heat Sink
IL
-
TC=25ºC
TC=99ºC
IL(99)
IL=1A, IF=10mA
RON
-
VL=600V
ILEAK
-
Turn-On
Turn-Off
IF=20mA, VL=10V
TON
TOFF
-
-
Output Capacitance
V=25V, f=1MHz
COUT
-
Input Characteristics
TA=25°C
Input Control Current 3
IL=1.0A
IF
-
Input Dropout Current
-
IF
0.6
Input Voltage Drop
IF=5mA
VF
0.9
Reverse Input Current
VR=5V
IR
-
Common Characteristics
TA=25°C
Capacitance Input to Output
-
CI/O
-
1 Higher load currents possible with proper heat sinking.
2 Measurement taken within 1 second of on time.
3 For applications requiring high temperature operation (greater than 60oC) an LED drive current of 20mA is recommended.
Typ
Max
Units
20
AP
1.5
-
15
ADC
2.0
0.35
0.5
Ω
-
1
µA
8
20
ms
0.15
5
3500
-
pF
-
10
mA
-
-
mA
1.2
1.4
V
-
10
µA
1
-
pF
2
www.clare.com