3. BOARD SETUP
3.1 Power Supplies:
1) Verify that all power supplies are off before
making connections.
2) Connect a +3.3 V DC power supply to the
VD+/VA+ (J6) binding post and place jumper
J8 in the ADJUST position. This connection
may be omitted by setting J8 to the REG posi-
tion. VD+/VA+ will be derived from the on-
board +3.3V regulator.
3) Connect a +3.3 V to +5.0 V DC power supply
to the VL+ (J5) binding post and place jumper
J7 in the ADJUST position. This connection
may be omitted by setting J7 to the +5 V posi-
tion. VL+ will be derived from the +5 V bind-
ing post.
4) Connect a +5.0 V DC power supply to the +5 V
(J3) binding post.
5) Connect the common ground of the power sup-
plies to the GND (J4) binding post.
6) Apply power to the board. D9 should illumi-
nate indicating power is applied to VD+/VA+.
3.2 Hardware Mode Settings:
1) Place switch S1-H/S in the OPEN position.
2) Place switches S3-INPUT, S3-8416_PCM, S3-
NVSEL, S3-RXSEL1, S3-RXSEL0, S3-
TXSEL1, S3-TXSEL0, S1-M/S, S1-SFMT1,
S1-SFMT0, S4-8406_PCM, S4-TCBLD, S4-
CEN to the appropriate positions.
3) Press and release the RESET switch S3. The
board should now be setup for use in Hardware
Mode.
3.3 Software Mode Settings:
1) Place switch S1-H/S in the CLOSED position.
2) Place switches S1-M/S, S3-INPUT, S3-
8416_PCM, and S4-8406_PCM to the appro-
priate positions. All other switch setting do not
effect Software Mode operation.
3) Press and release the RESET switch S2. The
board should now be setup for use in Software
mode.
4) Connect a DB-25 parallel port cable from the
PCâs parallel port to J1 on the CDB8416.
3.3.1 Installing the Software:
1) Create a directory called CDB8416 anywhere
on your system.
2) Copy CDB8416.exe from the included CD into
this directory.
3) Run port95nt.exe from the CD. After running
the program the system will need to be restart-
ed.
4) If desired, create a shortcut to CDB8416.exe on
your desktop. You should now be able to run
CDB8416.exe.
5) Double-click on CDB8416.exe or its shortcut.
6) Click on the button on the lower right labeled
âAdvancedâ.
7) Select the LPT port you are using to connect to
the CDB8416.
8) Shut down the application, reset the board, and
then restart the application.
3.3.2 Verifying Board Operation:
1) In the âCS8416 AES Receiver Controlsâ win-
dow, select the check box âEnable Internal
Clocksâ (enables the RUN bit in the Clock
Control register).
2) In the âCS8406 AES Transmitter Controlsâ
window, select the check box âEnable Clocksâ
(enables the RUN bit in the Clock Control reg-
ister).
3) In the âCS8416 AES Receiver Controlsâ win-
dow, select the check box âGenerate
SCLK/LRCKâ. Make sure that switch S1-M/S
is in the OPEN position.
DS578DB2