English
Language : 

CDB8416 Datasheet, PDF (5/28 Pages) Cirrus Logic – Evaluation Board
CDB8416
1.7 LED Function Indicators
Several LEDs are provided to indicate board func-
tions. D9 indicates that power is present to the
VD+/VA+ section of the CS8416 and CS8406.
D11, D12, and D13 indicate the status of the
2. CONFIGURATION SETTINGS
NV/RERR, AUDIO, and 96 kHz output of the
CS8416 in Hardware Mode. See the CS8416 data
sheet for an explanation of the conditions that acti-
vate each of these outputs.
CONNECTOR
J3 (+5V)
J4 (GND)
J5 (VL+)
J6 (VD+/VA+)
J9, J16, J21
OPT1-OPT4
J2
J1
J20
J19
J10
J18
INPUT/OUTPUT
Input
Input
Input
Input
Input
Input
Input
Input/Output
Output
Output
Output
Input/Output
SIGNAL PRESENT
+5 Volt Supply for supporting circuitry
Ground connection from power supply
+3.3 to 5.0 Volt Digital Logic power for the CS8416 and CS8406
+3.3 Volt VD+/VA+ when not using the onboard regulator
Digital Audio Interface coaxial input
Digital Audio Interface optical input
Digital Audio Interface XLR input
Parallel port for connection to parallel port of PC
Digital Audio Interface optical output
Digital Audio Interface coaxial output
Digital Audio Interface XLR output
I/O for CS8416 and CS8406 PCM data and clocks
Table 1. System Connections
JUMPER
PURPOSE
POSITION
FUNCTION SELECTED
J7 Selects between using a separate supply for ADJUST Uses J5 to supply from +3.3V to +5.0V for VL+ Uses
VL+ or using the +5 Supply.
+5V J3 to supply +5V for VL+
J8 Selects between using a separate supply for
REG Uses the onboard +3.3V regulator for VD+/VA+
VD+/VA+ or using the onboard +3.3V regulator. ADJUST Uses J6 to provide the +3.3V supply for VD+/VA+
J12 Current measurement for CS8416 VA+
CLOSED Normal operation
OPEN Use J13 to measure CS8416 VA+ current
J13 Current measurement for CS8416 VD+
CLOSED Normal operation
OPEN Use J12 to measure CS8416 VD+ current
J17 Current measurement for CS8416 VL+
CLOSED Normal operation
OPEN Use J16 to measure CS8416 VL+ current
J14 Current measurement for CS8406 VD+
CLOSED Normal operation
OPEN Use J14 to measure CS8406 VD+ current
J15 Current measurement for CS8406 VL+
CLOSED Normal operation
OPEN Use J15 to measure CS8406 VL+ current
J11 Selects between coaxial or XLR output
XLR Selects XLR output on J10
COAX Selects coaxial output on J19
Table 2. CDB8416 Jumper Settings