CS4362
Selects the appropriate digital filter to maintain the standard 15 μs/50 μs digital de-emphasis filter re-
sponse at 32, 44.1 or 48 kHz sample rates. (see Figure 39)
De-emphasis is only available in Single-Speed Mode.
4.4.3
Soft Ramp-Down Before Filter Mode Change (RMP_DN)
Default = 0
0 - Disabled
1 - Enabled
Function:
A mute will be performed prior to executing a filter mode change. When this feature is enabled, this mute
is effected, similar to attenuation changes, by the Soft and Zero Cross bits in the Mode Control 3 register.
When disabled, an immediate mute is performed prior to executing a filter mode change.
Note: For best results, it is recommended that this feature be used in conjunction with the RMP_UP bit.
4.5 Invert Control (address 05h)
7
Reserved
0
6
Reserved
0
5
INV_B3
0
4
INV_A3
0
3
INV_B2
0
2
INV_A2
0
1
INV_B1
0
0
INV_A1
0
4.5.1
Invert Signal Polarity (Inv_Xx)
Default = 0
0 - Disabled
1 - Enabled
Function:
When enabled, these bits will invert the signal polarity of their respective channels.
4.6 Mixing Control Pair 1 (Channels A1 & B1)(address 06h)
Mixing Control Pair 2 (Channels A2 & B2)(address 09h)
Mixing Control Pair 3 (Channels A3 & B3)(address 0Ch)
7
Px_A=B
0
6
PxATAPI4
0
5
PxATAPI3
1
4
PxATAPI2
0
3
PxATAPI1
0
2
PxATAPI0
1
1
PxFM1
0
0
PxFM0
0
4.6.1
Channel A Volume = Channel B Volume (A=B)
Default = 0
0 - Disabled
1 - Enabled
Function:
The AOUTAx and AOUTBx volume levels are independently controlled by the A and the B Channel Vol-
ume Control Bytes when this function is disabled. The volume on both AOUTAx and AOUTBx are deter-
mined by the A Channel Attenuation and Volume Control Bytes (per A-B pair), and the B Channel Bytes
are ignored when this function is enabled.