READING DATA
Each time data is transferred into a DPP control
register currently held data is shifted out via the D0
pin, thus in every data transaction a read cycle
occurs. Note, however, that the reading process is
destructive. Data must be removed from the register
in order to be read. Figure 2 depicts a Read Only
cycle in which no change occurs in the DPP’s output.
This feature allows µPs to poll DPPs for their current
setting without disturbing the output voltage but it
assumes that the setting being read is also stored in
non-volatile memory so that it can be restored at the
end of the read cycle. In Figure 2 CS returns low
before the 13th clock cycle completes. In doing so the
non-volatile memory setting is reloaded into the DPP
wiper control register. Since this value is the same as
that which had been there previously no change in the
DPP’s output is noticed. Had the value held in the
control register been different from that stored in non-
volatile memory then a change would occur at the
read cycle’s conclusion.
TEMPORARILY CHANGE OUTPUT
The CAT522 allows temporary changes in DPP’s
output to be made without disturbing the settings
retained in non-volatile memory. This feature is parti–
cularly useful when testing for a new output setting
and allows for user adjustment of preset or default
values without losing the original factory settings.
Figure 3 shows the control and data signals needed
to effect a temporary output change. DPP wiper
settings may be changed as many times as required
and can be made to any of the two DPPs in any order
or sequence. The temporary setting(s) remain in
effect long as CS remains high. When CS returns low
all two DPPs will return to the output values stored in
non-volatile memory.
When it is desired to save a new setting acquired
using this feature, the new value must be reloaded
into the DPP wiper control register prior to
programming. This is because the CAT522’s internal
control circuitry discards from the programming
register the new data two clock cycles after receiving
it if no PROG signal is received.
Figure 2. Reading from Memory
to 1 2 3 4 5 6 7 8 9 10
11 12
CS
DI
1 A0 A1
CURRENT DPP DATA
DO
D0 D1 D2 D3 D4 D5 D6 D7
PROG
RDY/BSY
DPP
OUTPUT
CURRENT
DPP VALUE
NON-VOL ATILE
Figure 3. Temporary Change in Output
to 1 2 3 4 5 6 7 8 9 10
11 12
N N+1 N+2
CS
DI
DO
PROG
RDY/BSY
DPP
OUTPUT
NEW DPP DATA
1 A0 A1 D0 D1 D2 D3 D4 D5 D6 D7
CURRENT DPP DATA
D0 D1 D2 D3 D4 D5 D6 D7
CURRENT
DPP VALUE
NON-VOL ATILE
NEW
DPP VALUE
VOLATILE
CURRENT
DPP VALUE
NON-VOL ATILE
Doc. No. MD-2004 Rev. G
8
© Catalyst Semiconductor, Inc.
Characteristics subject to change without notice