English
Language : 

CAT5241 Datasheet, PDF (4/16 Pages) Catalyst Semiconductor – Quad Digitally Programmable Potentiometers (DPP™) with 64 Taps and 2-wire Interface
CAT5241
D.C. OPERATING CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol
ICC
ISB
ILI
ILO
VIL
VIH
VOL1
Parameter
Test Conditions
Min
Power Supply Current
fSCL = 400kHz
Standby Current (VCC = 5.0V) VIN = GND or VCC; SDA Open
Input Leakage Current
VIN = GND to VCC
Output Leakage Current
VOUT = GND to VCC
Input Low Voltage
-1
Input High Voltage
VCC x 0.7
Output Low Voltage (VCC = 3.0V)
IOL = 3 mA
Typ Max Units
1
mA
1
µA
10
µA
10
µA
VCC x 0.3 V
VCC + 1.0 V
0.4
V
CAPACITANCE
TA = 25°C, f = 1.0 MHz, VCC = 5V
Symbol Test
CI/O(1) Input/Output Capacitance (SDA)
CIN(1) Input Capacitance (A0, A1, A2, A3, SCL)
Conditions Min Typ
Max Units
VI/O = 0V
8
pF
VIN = 0V
6
pF
A.C. CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
fSCL
Clock Frequency
TI(1)
Noise Suppression Time Constant at SCL, SDA Inputs
tAA
tBUF(1)
SLC Low to SDA Data Out and ACK Out
Time the Bus Must be Free Before a New
Transmission Can Start
tHD:STA Start Condition Hold Time
tLOW
Clock Low Period
tHIGH
Clock High Period
tSU:STA Start Condition SetupTime (For a Repeated Start Condition)
tHD:DAT Data in Hold Time
tSU:DAT
tR(1)
tF(1)
Data in Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
tSU:STO Stop Condition Setup Time
tDH
Data Out Hold Time
Min Typ
1.2
0.6
1.2
0.6
0.6
0
100
0.6
50
Max
400
50
0.9
Units
kHz
ns
µs
µs
µs
µs
µs
µs
ns
ns
0.3
µs
300
ns
µs
ns
POWER UP TIMING (1)
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
Min
tPUR Power-up to Read Operation
tPUW Power-up to Write Operation
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
Typ
Max
1
1
Units
ms
ms
Document No. 2011, Rev. J
4