English
Language : 

S111-0320XYZ-BB Datasheet, PDF (1/9 Pages) C&D Technologies – DC/DC Converter 3.3V input, 0.8 to 2.5V output, 10A; 5V input, 1.0 to 3.3V output, 10A
Features
✓ High output 10A
✓ 3.3V ±10%, 5V ±10% Input
✓ Regulation ±0.4% line and load
✓ Industry standard pin configuration
✓ High efficiency to 90%
✓ Remote Sense, Trim and Enable
✓ Short Circuit protection
✓ MTBF 2.9 million hours
✓ Can Source and Sink Output Current
DC/DDCC/DCCoCnovnevretreterr
Programmable, Single Output, 1.1V - 1.85Vout @ 60A
3.3V input, 0.8 to 2.5V output, 10A; 5V input, 1.0 to 3.3V output, 10A
This product is not fuse protected. User is responsible for providing system protection.
Consult factory for application information.
Specifications *
S111-03
S111-05
Input Specifications
Input voltage range
External input capacitor
Output Specifications
Standard output voltages
Output current
Load regulation
Line regulation
External output capacitor
Short circuit protection
3.3V ± 10%*
5.0V ± 10%
Minimum 500 µF with adequate
ripple current rating
0.8V
0.9V
1.0V
1.2V
1.2V
1.5V
1.5V
1.8V
1.8V
2.1V
2.1V
2.5V
2.5V
3.3V
10A
10A
±0.5%
±0.5%
>150µF with maxESR = 100mΩ
13A (at 70°C) to 20A (at -40°C)
Measured at +Vin pin
See also note on pg 8 and charts on pg 6
Standard setpoint accuracy varies from ±1.5%
at the low end of the output voltage range, to
±3% at the high end. (see chart on pg 2)
Contact factory for tighter tolerances.
See note on pg 7 for trimming to different volt-
ages.
200 LFM at 70°C (see also derating curves)
0 to 10A load
Over specified input voltage range
See also note on pg 8
General Specifications
Enable ***
Efficiency
Isolation
Switching frequency
Approvals and Standards
Protection
Operating Temperature ****
Storage Temperature
Weight
MTBF
ON-open or low / OFF-high (max 15V)
90% typical
Non-isolated
300kHz
UL 94V-0
Fusing
-40°C to 70°C
-40°C to 85°C
0.3 oz (8.5 gm)
3.8 million hours
See efficiency curves on pg 4
Fixed
Unit is not fused.
200 LFM at 70°C (see also derating curves)
Non-condensing
Per RAC PRISM at 50°C ambient and 200 LFM
* All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
*** Pull below 0.4V and sink greater than 50 µA or leave open to enable the SIP; pull above 2V (do not exceed 15V) and source greater than 150 µA
to disable the SIP.
**** The output capacitors must meet the max ESR = 100 mΩ requirement over the operating temperature range.
1150 Eglinton Avenue East
Toronto, Ontario M3C 1H7
1-866-740-1232
S111_084-S111-00_RevG_Jan18-2005.fm
www.cdtechno-cps.com
4607 S.E. International Way
Milwaukie, Oregon 97222
1-971-206-2800
1 of 9