8 APPENDIX A: EXTERNAL FILTERS
8.1 ADC Input Filter
The analog modulator samples the input at 6.144 MHz (internal MCLK=12.288 MHz). The digital filter will
reject signals within the stopband of the filter. However, there is no rejection for input signals which are
multiples of the digital passband frequency (n × 6.144 MHz), where n=0,1,2,... Refer to Figures 19 and 20
for a recommended analog input filter that will attenuate any noise energy at 6.144 MHz, in addition to
providing the optimum source impedance for the modulators. Refer to Figures 21 and 22 for low cost, low
component count passive input filters. The use of capacitors which have a large voltage coefficient (such
as general-purpose ceramics) must be avoided since these can degrade signal linearity.
634 Ω
100 kΩ
4.7 µF
470 pF
C0G
-
+
VA
100 kΩ
10 kΩ
91 Ω
634 Ω
100 kΩ
0.1 µF
100 µF 332 Ω
634 Ω
470 pF
C0G
-
+
91 Ω
2700 pF
C0G
ADC1-2
AINx+
AINx-
Figure 19. Single to Differential Active Input Filter
100 k Ω
VA
100 k Ω
4.7 µF
100 k Ω
470 pF
634 Ω
C0G
-
91 Ω
+
2700 pF
C0G
ADC1-2
AIN1+,2+,3+,4+
4.7 µF
AIN1-,2-,3-,4-
Figure 20. Single-Ended Active Input Filter
DS673PP2
49