English
Language : 

HB50-12 Datasheet, PDF (3/8 Pages) Broadband TelCom Power, Inc. – 12Vin 2.5, 3.3, 5.0, 12, 15, 24Vout 50W
Technical Specification
HB50-12 Series
12Vin 2.5, 3.3, 5, 12, 15, 24Vout 50W
Electrical Specification
Typical test data at Ta=25°C, Vin=12V unless otherwise noted.
PARAMETER
NOTES
MIN
Absolute maximum rating
Input voltage
0
Operating case temperature
-40
Storage temperature
-40
Humidity
Input characteristics
Operating input voltage range
9
Turn on voltage threshold
8.8
Turn off voltage threshold
Off converter input current
Output characteristics
12Vin
Output voltage
HB50-12-25 or HB50-12-25N
9-18Vin, no load to full load
2.47
HB50-12-33 or HB50-12-33N
9-18Vin, no load to full load
3.25
HB50-12-05 or HB50-12-05N
9-18Vin, no load to full load
4.85
HB50-12-12 or HB50-12-12N
9-18Vin, no load to full load
11.7
HB50-12-15 or HB50-12-15N
9-18Vin, no load to full load
14.5
HB50-12-24 or HB50-12-24N
9-18Vin, no load to full load
23.5
Output current
HB50-12-25 or HB50-12-25N
0
HB50-12-33 or HB50-12-33N
0
HB50-12-05 or HB50-12-05N
0
HB50-12-12 or HB50-12-12N
0
HB50-12-15 or HB50-12-15N
0
HB50-12-24 or HB50-12-24N
0
BTCPowerTM
TYP MAX UNIT
24
V
100
°C
105
°C
95
%
24
V
V
8.2
V
5
mA
2.50
2.53
V
3.30
3.35
V
5.00
5.15
V
12.0
12.3
V
15.0
15.5
V
24.0
24.5
V
10
A
10
A
10
A
4.16
A
3.33
A
2.08
A
Output voltage trim range
Output voltage ripple and noise
Output over power protection
Over-voltage protection
Over-temperature protection
Temperature coefficient
Output dynamic characteristics
Startup time
Transient recovery time
Transient Peak
Efficiency
HB50-12-25 or HB50-12-25N
HB50-12-33 or HB50-12-33N
HB50-12-05 or HB50-12-05N
HB50-12-12 or HB50-12-12N
HB50-12-15 or HB50-12-15N
HB50-12-24 or HB50-12-24N
Percentage of normal output
20Mz bandwidth, 100% Load, 12Vin, for 2.5,3.3,5,12,15V
For 24V
5% to 95% of the output voltage
25% load change (2.0A/us)
25% load change (2.0A/us)
-10
+10
%
100
150 mV(pk-pk)
240 mV(pk-pk)
110
120
140
%
130
150
%
105
110
°C
±0.05
%/°C
20
ms
800
µs
400
mv
76
%
78
%
81
%
84
%
84
%
84
%
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 3 of 8