ACPL-M61T-000E Datasheet, PDF (3/10 Pages) Broadcom Corporation. – 10MBd Wide Operating Temperature Automotive Digital Optocoupler with R2Coupler™ Isolation and AEC-Q100 Qualification
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision).
Note: Non-halide flux should be used.
Regulatory Information
The ACPL-M61T is approved by the following organizations:
UL
Approved under UL 1577, component recognition
program up to VISO = 4000 VRMS
CSA
Approved under CSA Component Acceptance Notice #5.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1
EN 60747-5-2:2001 + A1
DIN EN 60747-5-2 (VDE 0884 Teil 2)
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – III
I – II
Climatic Classification
55/125/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
567
Vpeak
Input to Output Test Voltage, Method b*
VPR
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
1063
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
VPR
907
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
VIOTM
6000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
TS
175
°C
Input Current
IS, INPUT
230
mA
Output Power
PS, OUTPUT 600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
:
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap (Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
(DIN VDE0109)
Symbol
L(101)
L(102)
CTI
ACPL-M61T Units
≥5
mm
≥5
mm
0.08
mm
175
V
IIIa
Conditions
Measured from input terminals to output terminals, shortest distance
through air.
Measured from input terminals to output terminals, shortest distance
path along body.
Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0109)
3