GMDC12V08 Datasheet, PDF (3/7 Pages) Bel Fuse Inc. – DORADO MV DC/DC CONVERTERS
DORADO MV DC/DC CONVERTERS
24V Input – 12VDC – 8A Output
POWER PRODUCTS
GMDC12V08
Isolation Specifications
Parameter
Isolation Test Voltage, Input/Baseplate/Output (Basic)
Isolation Resistance
Min
Typical
Max
2000
10
Units
VDC
MΩ
Features
Parameter
Over Temperature Protection, Thermal Sensor1
Switching Frequency, Fixed
1. PCB less than 130˚ C.
Min
Typical
Max
117
300
Units
˚C
kHz
General Specifications
Operating Temperature
Storge Temperature
Relative Humidity
Vibration
Material Flammability
Weight
MTBF Telcordia (Bellcore)
-40˚ C to + 100˚ C
-55˚ C + 125˚ C
10% to 95% RH, Non-condensing
2 to 9 Hz, 3mm disp., 9 to 200 Hz, 1g
UL V-0
30 grams
2.0 million hours
Approvals and Standards
UL and c-UL Recognized Component, TUV,
UL60950, CSA 22.2 No. 950, IEC/EN 60950**
EMC Characteristics:
Designed to meet emission and immunity
requirements per EN55022, CISPR 22,
Class B, and CISPR 24.
** An external fuse shall be used to comply with
the requirements.
©2006 Bel Fuse Inc. Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com
page 3