English
Language : 

SLIN-20E1A_10 Datasheet, PDF (20/26 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /20 A Outputs
December 10, 2010
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Tunable LoopTM (continued)
Table 2.General recommended values of RTUNE and CTUNE for Vin=12V and various external ceramic capacitor
combinations.
Co
RTUNE
CTUNE
1x47μF
240
1500pF
2x47μF
240
2700pF
4x47μF 10x47μF 20x47μF
240
150
150
5600pF 12nF 15nF
Table 3.Recommended values of RTUNE and CTUNE to obtain transient deviation of ≤2% of Vout for a 10A step
load with Vin=12V.
Vo
Co
RTUNE
CTUNE
ΔV
5V
6x47μF
220
5600pF
99mV
3.3V
5x47μF + 330μF
Polymer
220
7500pF
66mV
2.5V
2x330μF
Polymer
200
18nF
50mV
1.8V
1.2V
6x47μF + 2x 330μF 6x47μF + 4x330μF
Polymer
Polymer
150
150
33nF
120nF
36mV
24mV
0.69V
12x330μF
Polymer
150
120nF
12mV
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is
shown below.
Wind Tunnel
25.4_
(1.0)
PWBs
Power Module
76.2_
(3.0)
x
12.7_
(0.50)
Air
flow
Probe Location
for measuring
airflow and
ambient
temperature
Thermal Test Setup
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
20