SLIN-20E1A_10 Datasheet, PDF (2/26 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /20 A Outputs
December 10, 2010
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Unit
Continuous Input Voltage
-0.3
-
15
V
Notes
Voltage on SEQ terminal
-0.3
-
VIN
V
Voltage on SYNC terminal
-0.3
-
12
V
Voltage on PG terminal
-0.3
-
6
V
Operating Ambient Temperature
-40
-
85
°C
Storage Temperature
-55
-
125
°C
Note: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These
are absolute stress ratings only, functional operation of the device is not implied at these or any other
conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute
maximum ratings for extended periods can adversely affect the device reliability.
Input Specifications
Parameter
Operating Input Voltage
Min
Typ
Max Unit
4.5
-
14
V
Notes
Input Current (full load)
-
-
20
A VIN=4.5V to 14V
Input Current (no load)
-
42
-
mA Vo=0.69V, VIN=10V, IO=0, module enabled
-
74
-
mA Vo=3.3V, VIN=12V, IO=0, module enabled
Input Stand-by Current
-
3
-
mA VIN = 12V, module disabled
Input Reflected Ripple Current
(pk-pk)
-
43
-
mA
5Hz to 20MHz, 1μH source impedance; VIN
=4.5 to 14V, IO= IOmax
I2t Inrush Current Transient
-
-
1
A2s
Input Ripple Rejection (120Hz)
-
45
-
dB
Turn-on Threshold
-
4.45
-
V
Turn-off Threshold
-
4.2
-
V
Hysteresis
-
0.25
-
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to
an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety
agencies require a fast-acting fuse with a maximum rating of 20A. Based on the information provided in this
data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and
temperature conditions.