Tunable LoopTM (continued)
Table 2.General recommended values of RTUNE and CTUNE for Vin=12V and various external ceramic capacitor
combinations.
Co
RTUNE
CTUNE
1x47μF
270
2200pF
2x47μF
180
4700pF
4x47μF
100
18nF
6x47μF
75
18nF
10x47μF
75
22nF
Table 3.Recommended values of RTUNE and CTUNE to obtain transient deviation of ≤2% of Vout for a 1.5A step
load with Vin=12V.
Vo
Co
RTUNE
CTUNE
ΔV
5V
1x22μF
270
820pF
100mV
3.3V
1x47μF
270
2200pF
64mV
2.5V
2x47μF
180
4700pF
37mV
1.8V
2x47μF
150
4700pF
36mV
1.2V
3x47μF
150
10nF
22mV
0.6V
1x47μF+330μF
Polymer
100
15nF
12mV
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel.
Wind Tunnel
25.4_
(1.0)
PWBs
Power Module
76.2_
(3.0)
x
12.7_
(0.50)
Air
flow
Probe Location
for measuring
airflow and
ambient
temperature
Thermal Test Setup
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com