English
Language : 

SLIN-03E1A_10 Datasheet, PDF (2/26 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.59 Vdc - 5.5 Vdc /3 A Outputs
December 3, 2010
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Unit
Notes
Continuous Input Voltage
-0.3
-
15
V
Sequencing Voltage
-0.3
-
Vin
V
Operating Ambient Temperature
-40
-
85
°C
Storage Temperature
-55
-
125
°C
Note: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These
are absolute stress ratings only, functional operation of the device is not implied at these or any other
conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute
maximum ratings for extended periods can adversely affect the device reliability.
Input Specifications
Parameter
Operating Input Voltage
Min
Typ
Max Unit
4.5
-
14
V
Notes
Input Current (full load)
-
Input Current (no load)
Vo=0.6V
-
Vo=3.3V
-
-
3.5
A VIN=4.5V to 14V
17
-
mA VIN=12V, module enabled
55
-
mA
Input Stand-by Current
-
1
-
mA VIN = 12.0Vdc, module disabled
Input Reflected Ripple Current
(pk-pk)
-
43
5Hz to 20MHz, 1μH source
-
mA impedance; VIN =0 to 14V, IO= IOmax ;
See Test Configurations
I2t Inrush Current Transient
-
-
1
A2s
Input Ripple Rejection (120Hz)
-
50
-
dB
Turn-on Threshold
-
-
4.3
V
Turn-off Threshold
3.3
-
-
V
Hysteresis
0.4
-
-
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to
an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a fast-acting fuse with a maximum rating of 5A. Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can
be used. Refer to the fuse manufacturer’s data sheet for further information.
Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and
temperature conditions.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
2