2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Storage Temperature
Operating Ambient Temperature
Symbol
TST
TOP
Value
Min.
Max.
-40
80
-30
70
Unit
Note
ºC
(0), (1)
ºC (0), (1), (2)
Test Item
High Temperature Storage Test
Low Temperature Storage Test
Thermal Shock Storage Test
High Temperature Operation Test
Low Temperature Operation Test
High Temperature & High Humidity
Operation Test
Heat Cycle Operation Test
ESD Test (Operation)
Shock (Non-Operating)
Vibration (Non-Operating)
Test Condition
80ºC, 240 hours
-40ºC, 240 hours
-40ºC, 0.5hour 80 , 0.5hour; 100cycles, 1hour/cycle
70ºC, 240 hours
-30ºC, 240 hours
Note
(1), (2)
60ºC, RH 90%, 240hours
-30ºC, 1hour 70ºC, 1hour; 50cycles, 4hour/cycle
150pF, 330 , 1sec/cycle
Condition 1 : panel contact, 8KV
Condition 2 : panel non-contact 15KV
50G, 11ms, half sine wave, 1 time for ± X, ± Y, ± Z direction
1.5G, 10 ~ 500 Hz sine wave, 1.5mm Max, 30min/cycle, 1
cycles each X, Y, Z direction
(2)
(2), (3)
(2), (3)
Note (0) All test conditions are as above table.
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta ≤ 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation of water.
Note (2) No display malfunctions.
Note (3) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
Note (4) Temperature of panel display surface area should be 80 ºC Max.
6 / 27
Version 2.0