English
Language : 

G121S1-L01 Datasheet, PDF (18/26 Pages) AZ Displays – TFT LCD Approval Specification
Note (1) Definition of Viewing Angle (θx, θy):
Normal
θx = θy = 0º
θX- = 90º x-
θy-
θy+
θx−
θx+
DOC No.:14068027
Issued Date: Nov. 07, 2006
Model No.: G121S1-L01
Approval
12 o’clock direction
y+
θy+ = 90º
6 o’clock y-
θy- = 90º
x+ θX+ = 90º
Note (2) Definition of Contrast Ratio (CR):
The contrast ratio can be calculated by the following expression.
Contrast Ratio (CR) = L63 / L0
L63: Luminance of gray level 63
L 0: Luminance of gray level 0
CR = CR (5)
CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (6).
Note (3) Definition of Response Time (TR, TF) and measurement method:
100%
90%
Optical
Response
Gray Level 63
10%
0%
Gray Level 0
TF
66.67 ms
18 / 26
Gray Level 63
TR
66.67 ms
Time
Version 3.1