English
Language : 

HCPL-3000 Datasheet, PDF (9/10 Pages) Agilent(Hewlett-Packard) – Power Bipolar Transistor Base Drive Optocoupler
5.4
5.4
VCC = 6 V
VCC = 6 V
TA = 25°C
IF = 5 mA
5.3
IF = 5 mA
5.3
5.2
5.2
IO2 = -0.1 A
5.1
5.1
-0.4 A
5.0
5.0
-0.5 A
4.9
4.9
4.8
0
-0.1 -0.2 -0.3 -0.4 -0.5 -0.6
OUTPUT 2 CURRENT I02 (A)
4.8
-25
0
25
50
75
100
AMBIENT TEMPERATURE TA (°C)
Figure 18. Typical high level output 2 voltage
vs. output 2 current.
Figure 19. Typical high level output 2 voltage
vs. ambient temperature.
0.4
VCC = 6 V
TA = 25°C
0.2 IF = 0 mA
0.1
0.05
0.02
0.01
0.005
0.01 0.02
0.05 0.1 0.2
0.5 1.0
OUTPUT 2 CURRENT I02 (A)
Figure 20. Typical low level output 2 voltage
vs. output 2 current.
0.5
VCC = 6 V
IF = 0 mA
0.4
0.3
IO2 = 0.6 A
0.5 A
0.2
0.1
0
-25
0
0.1 A
25
50
75
100
AMBIENT TEMPERATURE TA (°C)
14
IF = 5 mA
12
10
TA = -20°C
25°C
8
80°C
6
4
4
6
8
10
12
14
SUPPLY VOLTAGE VCC (V)
Figure 21. Typical low level output 2 voltage
vs. ambient temperature.
Figure 22. Typical high level supply current
vs. supply voltage.
16
IF = 0 mA
14
TA = -20°C
12
25°C
10
8
80°C
6
4
6
8
10
12
14
SUPPLY VOLTAGE VCC(V)
Figure 23. Typical low level supply current vs.
supply voltage.
6
VCC = 6 V
5
RL1 = 5 Ω
R L2 = 10 Ω
4
IF = 5 mA
t PHL
TA = 80°C
3
25°C
2
-20°C
t PLH
1
0
TA = 80°C
25°C -20°C
0
5
10
15
20
25
FORWARD CURRENT IF (mA)
Figure 24. Typical propagation delay time vs.
forward current.
5
VCC = 6 V
R L1 = 5 Ω
4
RL2 = 10 Ω
IF = 5 mA
3
t PLH
2
t PHL
1
0
-25
0
25
50
75
100
AMBIENT TEMPERATURE TA (°C)
Figure 25. Typical propagation delay time vs.
ambient temperature.
9