English
Language : 

HCPL-3000 Datasheet, PDF (5/10 Pages) Agilent(Hewlett-Packard) – Power Bipolar Transistor Base Drive Optocoupler
+5 V
240 Ω
1
HCPL-3000
Q2
CONTROL
INPUT
TTL
OR
LSTTL
2
Q1
TOTEM
POLE
OUTPUT
1 GATE
R1 = 5 - 250 Ω
R2 = 1 - 2 Ω
BYPASS CAPACITOR C1 = 0.1 µF
8
C1
7
6
I O1
R2
5
R1
VCC (+ 5.4 V + 13 V)
POWER TRANSISTOR
MODULE
Figure 1. Recommended output transistor protection and typical application circuit.
+ HVDC
3-PHASE
AC
- HVDC
Electrical Specifications
Over recommended temperature (TA = -20°C to +80°C) unless otherwise specified.
Parameter
Sym. Min. Typ. Max. Units
Test Conditions
Input Forward Voltage
VF
-
1.1
1.4
V IF = 5 mA, TA = 25°C
0.6 0.9
-
V IF = 0.2 mA, TA = 25°C
Input Reverse Current
IR
-
-
10 µA VR = 3 V, TA = 25°C
Input Capacitance
CIN
-
30 250 pF VF = 0 V, f = 1 kHz,
TA = 25°C
Output 1
Low Level VO1L
-
0.2
0.4
V VCC = 6 V, IO1 = 0.4 A,
Voltage
RL2 = 10 Ω, IF = 5 mA
Leakage
Current
IO1L
-
-
200 µA VCC = VO1 = 13 V, VO2 = 0 V,
IF = 0 mA
Output 2
High Level VO2H 4.5
5.0
-
V VCC = 6 V, IO2 = -0.4 A
Voltage
IF = 5 mA, VO1 = 6 V
Low Level VO2L
-
0.2
0.4
V VCC = 6 V, IO2 = 0.5 A,
Voltage
IF = 0 mA
Leakage
Current
IO2L
-
-
200 µA VCC = 13 V, IF = 5 mA,
VO2 = 13 V
Supply
Current
High Level ICCH
-
-
9
13 mA TA = 25°C
-
17
VCC = 6 V, IF = 5 mA
Low Level
ICCL
-
11
15 mA TA = 25°C
Low to High IFLH
Threshold Input
Current
-
-
20
VCC = 6 V, IF = 0 mA
0.3
1.5
3.0 mA TA = 25°C
0.2
-
5.0 mA VCC = 6 V, RL1 = 5 Ω,
RL2 = 10 Ω
Fig. Note
13
2, 16, 2
17
4
3, 18, 2
19
20,
21
5
22 2
23
6, 14, 3
15
5