Switching Specifications
Over recommended operating temperature (TA = -40°C to +85°C) unless otherwise specified.
Parameter
Symbol Min. Typ.* Max. Units   Test Conditions
Input Current Threshold
ITHL
1.5
3.0
mA VCC = 5.5 V, VO = 0.6 V,
High to Low IO >13 mA (Sinking)
Propagation Delay
tPLH
52
100
ns IF = 3.5 mA
Time to High Output VCC = 5.0 V,
Level VE = Open,
Propagation
Time to Low
ODueltapyut tP HL 53 100 ns CRLL == 1355 0pFΩ,
Level
Pulse Width Distortion
PWD
|tPHL - tPLH|
11
45
ns
Propagation Delay Skew
tPSK
60
ns
Output Rise Time
tR
42
ns
Output Fall Time
tF
12
ns
Propagation Delay
tEHL
19
ns IF = 3.5 mA
Time of Enable VCC = 5.0 V,
from VEH to VEL
VEL = 0 V, VEH = 3 V,
Propagation Delay
tELH
30
ns CL = 15 pF,
Time of Enable RL = 350 Ω
from VEL to VEH
*All typical values at TA = 25°C, VCC = 5 V.
Fig. Note
7, 10 18
9, 11, 4, 9,
12 18
9, 11, 4, 10,
12 18
9, 13 17, 18
24 11, 18
9, 14 4, 18
9, 14 4, 18
15, 12
16
15, 12
16
Common Mode Transient Immunity Specifications, All values at TA = 25°C
Parameter
Device Symbol Min. Typ. Max. Units    Test Conditions
Fig. Note
Output High
Level Common
Mode Transient
Immunity
HCPL-261A |CMH|
HCPL-061A
1
5 kV/µs VCM = 50 V
HCPL-263A
HCPL-063A
HCPL-261N
HCPL-061N
1
5 kV/µs VCM = 1000 V
VCC = 5.0 V,
17
RL = 350 Ω,
IF = 0 mA,
TA = 25°C
VO(MIN) = 2 V
4, 13,
15, 18
HCPL-263N
15 25 kV/µs
Using Avago
20 4, 13,
HCPL-063N
App Circuit 15
Output Low
Level Common
Mode Transient
Immunity
HCPL-261A |CML|
HCPL-061A
1
5 kV/µs VCM = 50 V
HCPL-263A
HCPL-063A
HCPL-261N
HCPL-061N
1
5 kV/µs VCM = 1000 V
VCC = 5.0 V,
17
RL = 350 Ω,
IF = 3.5 mA,
VO(MAX) = 0.8 V
TA = 25°C
4, 14,
15, 18
HCPL-263N
15 25 kV/µs
Using Avago
20 4, 14,
HCPL-063N
App Circuit 15