ASSR-4128-302E Datasheet, PDF (9/11 Pages) AVAGO TECHNOLOGIES LIMITED – Form A, Solid State Relay (Photo MOSFET) (400V/0.10A/35Ohm)
Electrical Specifications (DC)
For operating TA = +25°C
Parameter
Output Withstand
Voltage
Output Leakage
Current
Input Reverse
Breakdown Voltage
Input Forward
Voltage
Output
On-resistance
Sym.
|VO(OFF)|
Min. Typ.
400 450
Max. Units Conditions
V
VF =0.8V, IO=250 A
IO(OFF)
0.005 1
A
VF =0.8V, VO=400V
VR
5
V
IR =10 A
VF
1.1 1.3
1.6
V
IF =5mA
R(ON)
ASSR-4119
Connection B
25
35

IF =5mA, IO=100mA,
Pulse 30ms
8
10

IF =5mA, IO=200mA,
Pulse 30ms
Fig. Note
5
6, 7
8, 9 6
Switching Specifications (AC)
For operating TA = +25°C
Parameter
Sym.
Min. Typ.
Max. Units Conditions
Fig.
Note
Turn On Time
TON
Turn Off Time
TOFF
0.7
5.0
ms
IF =5mA, IO=100mA
0.04
5.0
ms
IF =5mA, IO=100mA
Notes:
1. For derating, refer to Figure 1, 2, 3 and 4.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should
be added in some applications to protect against over-voltage transients.
3. Threshold to switch device is IF  0.5mA, however, for qualified device performance over temperature range, it is recommended to operate at
IF =5mA.
4. Device is considered as a two terminal device:
ASSR-4118 - pin 1, 2 shorted and pin 3, 4 shorted.
ASSR-4119 - pin 1, 2, 3 shorted and pin 4, 5, 6 shorted.
ASSR-4128 - pin 1, 2, 3, 4 shorted and pin 5, 6, 7, 8 shorted.
5. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
6. During the pulsed R(ON) measurement ( IO duration 30ms), ambient (TA) and case temperature (TC) are equal.
9