English
Language : 

HCNW136-300E Datasheet, PDF (8/16 Pages) AVAGO TECHNOLOGIES LIMITED – Single Channel, High Speed Optocouplers
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (OPTION 060 ONLY)*
Description
Symbol 8 Pin DIP SO-8 Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
I – IV
I – IV
I – IV
0/70/21
I – IV
I – IV
I – III
0/70/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM × 1.875 = VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM × 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage* (Transient Overvoltage tini = 60 sec)
Safety-limiting values – maximum values allowed in the event of a failure
VIORM
630
VPR
1181
VPR
1008
VIOTM
8000
567
Vpeak
1063 Vpeak
907
Vpeak
6000 Vpeak
Case Temperature
TS
175
150 °C
Input Current
IS, INPUT 230
150 mA
Output Power
PS, OUTPUT 600
600 mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
≥ 109 Ω
* Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (HCNW135/6 OPTION 060 ONLY)*
Description
Symbol Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
I – IV
I – IV
I – IV
I – III
0/70/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM × 1.875 = VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM × 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage* (Transient Overvoltage tini = 60 sec)
Safety-limiting values – maximum values allowed in the event of a failure
VIORM 1414
Vpeak
VPR
2651
Vpeak
VPR
2262
Vpeak
VIOTM 8000
Vpeak
Case Temperature
TS
150
°C
Input Current
IS, INPUT 400
mA
Output Power
PS, OUTPUT 700
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
Ω
* Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
8