ACPL-K370 Datasheet, PDF (8/13 Pages) AVAGO TECHNOLOGIES LIMITED – Isolated Voltage/Current Detector
Table 8. Package Characteristics
Over recommended temperature range of TA = –40°C to 105°C unless otherwise specified.
Parameter
Symbol Min
Typ
Max
Units Test Conditions
Input-Output Momentary
VISO
Withstand Voltage
5000
Vrms
RH ≤ 50%, t = 1 min; TA = 25°C;
Notes 1 to 3
Input-Output Resistance
RI-O
1012
:
VI-O = 500 Vdc; Note 2
Input-Output Capacitance CI-O
0.6
pF
f = 1 MHz, VI-O = 0 Vdc; Note 2
Notes:
1. The input-output momentary withstand voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-5 Insulation Characteristics Table (if applicable), your equipment level
safety specification, or Avago Application Note 1074, Optocoupler Input-Output Endurance Voltage.
2. Device considered a two terminal device: pins 1, 2, 3, 4 connected together, and pins 5, 6, 7, 8 connected together.
3. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 6000 Vrms for 1 second (leakage detection
current limit, II-O ≤ 5 PA).
8