Table 6. Electrical Specifications
Unless otherwise noted, TA = –40°C to +105°C and VCC = 3 V to 5.5 V.
Parameter
Sym. Device
Min Typ[1] Max Units Test Conditions/Notes
Fig.
Upper Threshold
Voltage, DC Input
(Pins 2, 3)
VTH+
3.6
3.8
(–5%)
3.35
4
V
(+5%)
4.05 V
TA = 25°C, VIN = VDC+ – VDC–;
5, 6
AC1 and AC2 open
VIN = VDC+ – VDC–; AC1 and AC2 open 5, 6
Lower Threshold
VTH–
Voltage, DC Input
(Pins 2, 3)
2.45 2.59
(–5%)
2.01
2.72 V
(+5%)
2.96 V
TA = 25°C, VIN = VDC+ – VDC–;
5, 6
AC1 and AC2 open
VIN = VDC+ – VDC–; AC1 and AC2 open 5, 6
Upper Threshold
Voltage, AC Input
(Pins 1, 4)
VTH+
4.7
5
(–6%)
4.23
5.3
V
(+6%)
5.5
V
TA = 25°C, VIN = VAC1 – VAC2,
5, 6
DC+ and DC– open; Note 2
VIN = VAC1 – VAC2, DC+ and DC– open 5, 6
Lower Threshold
VTH–
Voltage, AC Input
(Pins 1, 4)
3.57 3.8
(–6%)
2.87
4.03 V
(+6%)
4.42 V
TA = 25°C, VIN = VAC1 – VAC2,
5, 6
DC+ and DC– open
VIN = VAC1 – VAC2, DC+ and DC– open 5, 6
Upper Threshold
ITH+ ACPL-K370 2.26 2.77 2.99 mA TA = 25°C
5, 6
Current
1.96
3.11 mA
5, 6
Upper Threshold
ITH+ ACPL-K376 1.03 1.32 1.46 mA TA = 25°C
5, 6
Current
0.87
1.56 mA
5, 6
Lower Threshold
ITH– ACPL-K370 1.09 1.44 1.59 mA TA = 25°C
5, 6
Current
1
1.62 mA
5, 6
Lower Threshold
ITH– ACPL-K376 0.48 0.68 0.77 mA TA = 25°C
5, 6
Current
0.43
0.8
mA
5, 6
Current Hysteresis
IHYS ACPL-K370
1.2
mA IHYS = ITH+ – ITH–
5
ACPL-K376
0.6
mA
Voltage Hysteresis
VHYS
1.2
V
VHYS = VTH+ – VTH–
5
Input Clamp Voltage VIHC1
5.4
6.1
6.8
V
VIHC1 = VDC+ – VDC–, IIN = 10 mA,
4
AC1 & AC2 connected to DC–
VIHC2
6.1
6.8
7.4
V
VIHC2 = |VAC1 – VAC2|, |IIN| = 10 mA,
4
DC+ and DC– open
VIHC3
12.5 13.4 V VIHC3 = VDC+ – VDC–, IIN = 15 mA,
4
AC1 & AC2 open
VILC
–0.76
V
VILC = VDC+ – VDC–, IIN = –10 mA
Input Current
IIN
ACPL-K370 3.2
3.9
4.4
mA VDC+ – VDC– = 5 V, AC1 and AC2 open 8
Input Current
IIN
ACPL-K376 1.5
1.9
2.2
mA VDC+ – VDC– = 5 V, AC1 and AC2 open 8
Bridge Diode
VD1,2 ACPL-K370
0.59
Forward Voltage
ACPL-K376
0.47
V IIN = 3 mA
V IIN = 1.5 mA
VD3,4 ACPL-K370
0.78
V IIN = 3 mA
ACPL-K376
0.73
V IIN = 1.5 mA
Logic Low Output
VOL
Voltage
0.05 0.4
V VCC = 4.5 V, IOL = 4.2 mA; Note 3
8
Logic High Output
IOH
Current
100
PA VOH = VCC = 18 V; Note 4
Logic Low Supply
ICCL ACPL-K370
0.9
4
mA VDC+ – VDC– = 5 V, VO open
9
Current
ACPL-K376
0.5
3
mA
Logic High Supply
ICCH
Current
0.002 4
PA VCC = 18 V, VO open
7
Input Capacitance
CIN
50
pF f = 1 MHz, VIN = 0 V
Notes:
1. All typical values are at TA = 25°C unless otherwise stated.
2. AC voltage is instantaneous voltage.
3. A logic “Low” output level at pin 6 occurs under the conditions of VIN ≥ VTH+ as well as the range of VIN > VTH– once VIN has exceeded VTH+.
4. A logic “High” output level at pin 6 occurs under the conditions of VIN ≤ VTH– as well as the range of VIN < VTH+ once VIN has decreased below VTH–.