English
Language : 

HCPL-2602 Datasheet, PDF (7/16 Pages) Agilent(Hewlett-Packard) – High CMR Line Receiver Optocouplers
Electrical Characteristics
Over recommended temperature (TA = 0°C to +70°C) unless otherwise specified. See note 1.
Parameter
Sym. Min. Typ.* Max. Units
Test Conditions
High Level Output
IOH
Current
Low Level Output
VOL
Voltage
High Level Supply
ICCH
Current
Low Level Supply
ICCL
Current
High Level Enable
IEH
Current
5.5
100
µA VCC = 5.5 V, VO = 5.5 V,
II = 250 µA, VE = 2.0 V
0.35
0.6
V
VCC = 5.5 V, II = 5 mA,
VE = 2.0 V,
IOL (Sinking) = 13 mA
7.5
10
mA VCC = 5.5 V, II = 0 mA,
VE = 0.5 V
10
13
mA VCC = 5.5 V, II = 60 mA,
VE = 0.5 V
-0.7
-1.6
mA VCC = 5.5 V, VE = 2.0 V
Low Level Enable
IEL
Current
-0.9
-1.6
mA VCC = 5.5 V, VE = 0.5 V
High Level Enable
VEH
2.0
V
Voltage
Low Level Enable
VEL
Voltage
0.8
V
Input Voltage
VI
Input Reverse
VR
Voltage
2.0
2.4
2.3
2.7
0.75 0.95
II = 5 mA
V
II = 60 mA
V
IR = 5 mA
Input Capacitance
CIN
90
pF VI = 0 V, f = 1 MHz
*All typicals at VCC = 5 V, TA = 25°C.
Fig. Note
1
2, 4,
5, 14
10
3
7