HCPL-788J Datasheet, PDF (6/20 Pages) AVAGO TECHNOLOGIES LIMITED – Isolation Amplifier with Short Circuit and Overload Detection SO-16 Package
Insulation and Safety Related Specifications
Parameter
Symbol Min.
Minimum External Air Gap
(Clearance)
L(101) 8.3
Minimum External Tracking
(Creepage)
L(102) 8.3
Minimum Internal Plastic Gap
0.5
Tracking Resistance
Isolation Group
CTI
>175
IIIa
Max.
mm
mm
mm
Volts
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance conductor to conductor,
usually the straight line distance thickness between the
emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Comparative Tracking Index)
Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Supply Voltages
Steady-State Input Voltage
2 Second Transient Input Voltage
Output Voltage
Absolute Value Output Voltage
Reference Input Voltage
Reference Input Current
Output Current
Absolute Value Current
FAULT Output Current
Input IC Power Dissipation
Output IC Power Dissipation
Symbol
T
S
T
A
V ,V
DD1 DD2
V ,V
IN+ IN-
VIN+, VIN-
V
OUT
ABSVAL
V
REF
I
REF
I
VOUT
I
ABSVAL
I
FAULT
P
I
P
O
Min.
-55
-40
0.0
-2.0
-6.0
-0.5
-0.5
0
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Supply Voltages
Input Voltage (accurate and linear)
Input Voltage (functional)
Reference Input Voltage
FAULT Output Current
Symbol
T
A
V ,V
DD1 DD2
V ,V
IN+ IN-
V ,V
IN+ IN-
V
REF
I
FAULT
Min.
-40
4.5
-200
-2
4.0
Max.
Units
Note
125
°C
100
°C
5.5
V
4
V + 0.5
V
DD1
VDD1 + 0.5
V
V + 0.5
V
DD2
V + 0.5
V
DD2
V + 0.5 V V
5
DD2
20
mA
20
mA
20
mA
20
mA
200
mW
200
mW
Max.
Units
Note
85
°C
5.5
V
200
mV
2
V
V
V
DD2
4
mA
6