English
Language : 

HCPL-4562-020 Datasheet, PDF (6/17 Pages) AVAGO TECHNOLOGIES LIMITED – High Bandwidth, Analog/Video Optocouplers
Insulation and Safety Related Specifications
8-Pin DIP
Widebody
(300 Mil)
(400 Mil)
Parameter
Symbol
Value
Value
Units
Minimum External
L(101)
7.1
9.6
mm
Air Gap (External
Clearance)
Minimum External
L(102)
7.4
10.0
mm
Tracking (External
Creepage)
Minimum Internal
0.08
1.0
mm
Plastic Gap
(Internal Clearance)
Minimum Internal
NA
4.0
mm
Tracking (Internal
Creepage)
Tracking Resistance
CTI
200
200
Volts
(Comparative
Tracking Index)
Isolation Group
IIIa
IIIa
Conditions
Measured from input terminals to
output terminals, shortest distance
through air.
Measured from input terminals to
output terminals, shortest distance
path along body.
Through insulation distance,
conductor to conductor, usually the
direct distance between the photo-
emitter and photodetector inside the
optocoupler cavity.
Measured from input terminals to
output terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group
(DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW4562 ONLY)
Description
Symbol
Installation classification per DIN VDE 0110/1.89, Table 1
  for rated mains voltage ≤ 600 V rms
  for rated mains voltage ≤ 1000 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
  VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
  Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
  VIORM x 1.5 = VPR, Type and sample test,
VPR
  tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VIOTM
Safety Limiting Values
  (Maximum values allowed in the event of a failure,
  also see Figure 17, Thermal Derating curve.)
   Case Temperature
   Input Current
   Output Power
TS
IS,INPUT
PS,OUTPUT
Insulation Resistance at TS, VIO = 500 V
RS
Characteristic
Units
I-IV
I-III
55/85/21
2
1414
Vpeak
2652
Vpeak
2121
Vpeak
8000
Vpeak
150
°C
400
mA
700
mW
≥ 109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN
60747-5-2, for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in
application.