English
Language : 

HCPL-4100 Datasheet, PDF (6/12 Pages) Agilent(Hewlett-Packard) – Optically Coupled 20 mA Optically Coupled 20 mA
Switching Specifications
For 0°C ≤ T ≤ 70°C, 4.5 V ≤ V ≤ 20 V, all typicals at T = 25°C and V = 5 V unless otherwise noted. See note 12.
A
CC
A
CC
Parameter
Symbol Min. Typ. Max. Units Test Conditions
Fig. Note
Propagation Delay Time
to Logic High Output Level
Propagation Delay Time
to Logic Low Output Level
Propagation Delay Time
Skew
t
PLH
t
PHL
t -t
PLH PHL
0.3
1.6 μs C = 1000 pF,
O
C = 15 pF,
L
I = 20 mA
O
0.2
1.0 μs C = 1000 pF,
O
C = 15 pF,
L
I = 20 mA
O
0.1
μs I = 20 mA
O
5, 6, 6
7
5, 6, 7
7
Output Rise Time
(10-90%)
Output Fall Time
(90-10%)
Common Mode Transient
Immunity at Logic High
Output Level
Common Mode Transient
Immunity at Logic Low
Output Level
t
16
r
t
23
f
|CM |
H
1,000 10,000
|CM |
L
1,000 10,000
ns I = 20 mA,
O
C = 1000 pF,
O
C = 15 pF
L
ns I = 20 mA,
O
C = 1000 pF,
O
C = 15 pF
L
V/μs V = 2 V,
I
T = 25°C
A
V = 50 V (peak),
CM
VCC = 5 V
I (min.) = 12 mA
O
V/μs V = 0.8 V,
I
T = 25°C
A
VCM = 50 V (peak),
V =5V
CC
I (max.) = 3 mA
O
6, 8
8
6, 8
9
9, 10 10
9, 10 11
Package Characteristics
For 0°C ≤ T ≤ 70°C, unless otherwise specified. All typicals at T = 25°C.
A
A
Parameter
Symbol Min. Typ. Max. Units
Input-Output Momentary
Withstand Voltage*
V
3750
ISO
V rms
Resistance, Input-Output
R
I-O
Capacitance, Input-Output
C
I-O
1012
ohms
1
pF
Test Conditions
RH ≤ 50%, t = 1 min,
T = 25°C
A
V = 500 V dc
I-O
f = 1 MHz,
V = 0 V dc
I-O
Fig. Notes
5, 13
5
5
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous volt-
age rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment
level safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
6