|
HCPL-3150 Datasheet, PDF (6/22 Pages) Agilent(Hewlett-Packard) – 0.5 Amp Output Current IGBT Gate Drive Optocoupler | |||
|
◁ |
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description
Symbol
Installation classification per DIN VDE
0110/1.89, Table 1
for rated mains voltage ⤠150 Vrms
â for rated mains voltage ⤠300 Vrms
â for rated mains voltage ⤠600 Vrms
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
â VIORM x 1.875 = VPR, 100% Production
Test with tm =â1âsec,
VPR
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
â VIORM x 1.5 = VPR, Type and Sample
Test, tm = 60 sec, VPR
945
â Partial discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage tini = 10 sec)
Safety-Limiting Values â Maximum Values
Allowed in the Event of a Failure, Also
See Figure 37, Thermal Derating Curve.
â Case TemperatureTS
â Input Current
â Output Power
Insulation Resistance at TS, VIO = 500 V
VIOTM
175
IS, INPUT
PS, OUTPUT
RS
HCPL-3150#060
I - IV
I - III
55/100/21
2
630
1181
1336
6000
175
230
600
⥠109
HCPL-315J
I - IV
I - IV
I - III
2
891
1670
Vpeak
6000
°C
400
1200
⥠109
Unit
Vpeak
Vpeak
Vpeak
mA
mW
â¦
*Refer to the front of the optocoupler section of the current Catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description of Method a and Method b partial discharge test profiles.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
|
▷ |