ASSR-1611 Datasheet, PDF (6/11 Pages) AVAGO TECHNOLOGIES LIMITED – High Current, 1 Form A, Solid State Relay (MOSFET) (60V/2.5A/0.1)
Electrical Specifications (DC)
Over recommended operating TA = - 40°C to 85°C, IF = 5mA to 10mA, unless otherwise specified.
Parameter
Output Withstand Voltage
Output Leakage Current
Sym. Min.
| VO(OFF)| 60
55
IO(OFF)
Output Off-Capacitance
Output Offset Voltage
Input Reverse Breakdown
Voltage
C(OFF)
| V(OS)|
VR
5
Input Forward Voltage
VF
1.1
Output On- Connection A R(ON)
resistance
Connection B
Typ. Max. Units Conditions
Fig. Note
68
V
VF=0.8V, IO=250μA, TA=25°C 3
V
VF=0.8V, IO=250μA
3
0.01 0.1
μA
VF=0.8V, VO=60V, TA=25°C 5
5
μA
VF=0.8V, VO=55V
4
1400
pF
VF=0.8V, VO=0V, f=1MHz 6
1
μV
IF=5mA, IO=0mA
V
IR=10μA
1.3
1.7
V
0.065 0.1
Ω
0.02 0.035 Ω
IF=5mA
IF=5mA, IO=2.5A,
Pulse ≤30ms, TA=25°C
7, 8
9, 10 5
11
Switching Specifications (AC)
Over recommended operating TA = - 40°C to 85°C, IF = 5mA to 10mA, unless otherwise specified.
Parameter
Sym. Min. Typ. Max. Units Conditions
Fig. Note
Turn On Time
Turn Off Time
TON
3.2
5.0
ms
IF=5mA, IO=1.0A, TA=25°C 12, 13
10.0
ms
IF=5mA, IO=1.0A
1.6
2.5
ms
IF=10mA, IO=1.0A, TA=25°C 12, 14
5.0
ms
IF=10mA, IO=1.0A
TOFF
0.1
0.5
ms
IF=5mA, IO=1.0A, TA=25°C 15, 16
1
0.06 0.2
ms
IF=5mA, IO=1.0A
ms
IF=10mA, IO=1.0A, TA=25°C 15, 17
0.5
ms
IF=10mA, IO=1.0A
Output Transient
dVO/dt 1
7
kV/μs ΔVO=60V, RM ≥ 1MΩ,
6
Rejection
CM=1000pF, TA=25°C
Input-Output
Transient Rejection
dVI-O/dt 1
≥10
kV/μs VDD=5V, ΔVI-O=1000V,
6
RL=1kΩ, CL=25pF, TA=25°C
Notes:
1. For derating, refer to Figure 1 and 2.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should be
added in some applications to protect against over-voltage transients.
3. Device is considered as a two terminal device: pins 1, 2, and 3 shorted together and pins 5, 6, and 7 shorted together.
4. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level
safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
5. During the pulsed R(ON) measurement ( IO duration ≤30ms), ambient (TA) and case temperature (TC) are equal.
6. For the transient rejection measurements, refer to Avago whitepaper, AV01-0610EN, “Solid State Relay Transient Immunity”.
6