ASSR-1611 Datasheet, PDF (1/11 Pages) AVAGO TECHNOLOGIES LIMITED – High Current, 1 Form A, Solid State Relay (MOSFET) (60V/2.5A/0.1) | |||
|
ASSR-1611
High Current, 1 Form A, Solid State Relay (MOSFET)
(60V/2.5A/0.1ï)
Data Sheet
Description
The ASSR-1611 is specifically designed for high current
applications, commonly found in the industrial equip-
ments. The relay is a solid-state replacement for single-
pole, normally-open, (1 Form A) electromechanical relays.
The ASSR-1611 consists of an AlGaAs infrared light-emit-
ting diode (LED) input stage optically coupled to a high-
voltage output detector circuit. The detector consists of a
high-speed photovoltaic diode array and driver circuitry
to switch on/off two discrete high voltage MOSFETs. The
relay turns on (contact closes) with a minimum input cur-
rent of 5mA through the input LED. The relay turns off
(contact opens) with an input voltage of 0.8V or less.
The ASSR-1611 connection A, as shown in the schematic,
allows the relay to switch either ac or dc loads. The con-
nection B, with its advantages of reduced on-resistance
and higher output current, allows the relays to switch dc
loads only.
The electrical and switching characteristics are specified
over the temperature range of -40°C to +85°C.
Functional Diagram
Opto-isolation
1
2
Truth Table
6
LED
Off
5
On
Output
Open
Close
3
4
Features
ï· Compact Solid-State Bi-directional Signal Switch
ï· Single Channel Normally-off Single-Pole-Single-Throw
(SPST) Relay
ï· 60V Output Withstand Voltage
ï· 2.5A or 5A Current Rating
ï· Low Input Current: CMOS Compatibility
ï· Low On-Resistance: 20mΩ Typical for DC-only, 65mΩ
Typical for AC/DC
ï· High Speed Switching: 3.2ms (Ton), 0.1ms (Toff) Typical
ï· High Transient Immunity: >1kV/μs
ï· High Input-to-Output Insulation Voltage
- (Safety and Regulatory Approvals)
UL recognized - 3750 VRMS and 5000 VRMS* for 1 min
per UL1577
- CSA Component Acceptance
*5000 VRMS/1 Minute rating is for Option X21 only.
(Please consult your regional Avago representatives)
Applications
ï· Industrial Controls
ï· Factory Automation
ï· Data Acquisition
ï· Measuring Instrument
ï· Medical System
ï· Security System
ï· EMR / Reed Relay Replacement
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
|
▷ |