English
Language : 

HFBR-53A3VEMZ Datasheet, PDF (5/13 Pages) AVAGO TECHNOLOGIES LIMITED – RoHS Compliant 3.3 V 1 x 9 Fiber Optic Transceivers for Fibre Channel
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each
parameter in isolation, all other parameters having values within the recommended operating conditions. It should not
be assumed that limiting values of more than one parameter can be applied to the product at the same time. Exposure
to the absolute maximum ratings for extended periods can adversely affect device reliability.
Parameter
Symbol
Min.
Typ.
Max.
Units
Reference
Storage Temperature
TS
-40
+100
°C
Supply Voltage
VCC
-0.5
5.0
V
1
Transmitter Differential Input Voltage
VD
2.2
V
Relative Humidity
RH
5
95
%
TTL Signal Detect Current – Low
TTL Signal Detect Current – High
IOL, MAX
-5
IOH, MAX
mA
4.0
mA
Recommended Operating Conditions
Parameter
Symbol
Min.
Typ.
Ambient Operating Temperature
TA
0
Case Temperature
TC
0
Supply Voltage
VCC
3.14
Power Supply Rejection
PSR
100
Transmitter Differential Input Voltage
VD
0.4
Received Data Output Load
RDL
50
TTL Signal Detect Output Current – Low
IOL
TTL Signal Detect Output Current – High
IOH
-400
Max.
Units
Reference
+70
°C
+80
°C
2
3.47
V
mVp-p
3
1.6
V
W
1.0
mA
mA
Process Compatibility
Parameter
Symbol
Min.
Typ.
Max.
Units
Reference
Hand Lead Soldering Temperature/Time
TSOLD/TSOLD
+260/10 °C/s
Wave Soldering and Aqueous Wash
TSOLD/TSOLD
+260/10 °C/s
4
Notes:
1. The transceiver is class 1 eye safe up to VCC = 5.0 V.
2. Case temperature measurement referenced to the metal housing.
3. Tested with a 100 mVP–P sinusoidal signal in the frequency range from 10 Hz to 2 MHz on the VCC supply with the recommended power supply
filter (with C8) in place. Typically less than a 1 dB change in sensitivity is experienced.
4. Aqueous wash pressure < 110 psi.