English
Language : 

HCPL-814 Datasheet, PDF (5/7 Pages) Agilent(Hewlett-Packard) – AC Input Phototransistor Optocoupler High Density Mounting Type
Electrical Specifications (TA = 25˚C)
Parameter
Symbol Min.
Typ.
Max.
Units
Test Conditions
Forward Voltage
VF
–
1.2
1.4
V
IF = ±20 mA
Terminal Capacitance
Ct
–
50
250
pF
V = 0, f = 1 kHz
Collector Dark Current
ICEO
–
–
100
nA
VCE = 20 V, IF = 0
Collector-Emitter Breakdown Voltage
BVCEO
35
–
–
V
IC = 0.1 mA, IF = 0
Emitter-Collector Breakdown Voltage
BVECO
6
–
–
V
IE = 10 µA, IF = 0
Collector Current
Current Transfer Ratio[2]
IC
0.2
–
CTR
20
–
3
mA
IF = ±1 mA,
300
%
VCE = 5 V
Collector-Emitter Saturation Voltage
VCE(sat)
–
0.1
0.2
V
Isolation Resistance
Riso
5 x 1010
1 x 1011
–
Ω
IF = ±20 mA, IC = 1 mA
DC 500 V
40 ~ 60% R.H.
Floating Capacitance
Cf
–
0.6
1
pF
V = 0, f = 1 MHz
Cut-off Frequency
fc
15
80
–
kHz
VCE = 5 V, IC = 2 mA
RL = 100 Ω, –3 dB
Response Time (Rise)
Response Time (Fall)
tr
–
4
18
µs
VCE = 2 V, IC = 2 mA,
tf
–
3
18
µs
RL = 100 Ω
Rank Mark
CTR (%)
A
50 ~ 150
No Mark
20 ~ 300
Conditions
IF = ±1 mA,
VCE = 5 V,
TA = 25˚C
Notes:
1. Isolation voltage shall be measured using the following method:
(a) Short between anode and cathode on the primary side and between collector and emitter
on the secondary side.
(b) The isolation voltage tester with zero-cross circuit shall be used.
(c) The waveform of applied voltage shall be a sine wave.
2. CTR = IICFx 100%
60
50
40
30
20
10
0
-30 0 25 50 75 100 125
TA – AMBIENT TEMPERATURE – °C
200
150
100
50
0
-30 0 25 50 75 100 125
TA – AMBIENT TEMPERATURE – °C
6
TA = 25°C
5
IC = 0.5 mA
4
IC = 1 mA
IC = 3 mA
3
IC = 5 mA
IC = 7 mA
2
1
0
0 2.5 5.0 7.5 10.0 12.5 15.0
IF – FORWARD CURRENT – mA
Figure 1. Forward curHreCnPt vLs-.8t1e4mfpiger1ature.
Figure 2. Collector powHeCrPdLis-s8ip1a4tifoign v2s. tempera-
ture.
Figure 3. Collector-emittHeCr sPaLtu-3ra5t4iofnigvo3ltage vs.
forward current.