Regulatory Information
The ACPL-31JT is approved by the following organizations:
UL
CSA
IEC/EN/DIN EN 60747-5-5
Approved under UL 1577, component recognition program up to VISO = 5000 VRMS
Approved under CSA Component Acceptance Notice #5, File CA 88324.
Approved under IEC 60747-5-5, EN 60747-5-5, DIN EN 60747-5-5
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics
Description
Insulation Classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150Vrms
for rated mains voltage ≤ 300Vrms
for rated mains voltage ≤ 600Vrms
for rated mains voltage ≤ 1000Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
VIORM x 1.875 = VPR, 100% Production Test with tm = 1sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
Safety-limiting values
– maximum values allowed in the event of a failure
Case Temperature
Input Power
Output Power
Insulation Resistance at TS, VIO = 500V
Symbol
VIORM
VPR
VPR
VIOTM
Characteristic
I – IV
I – IV
I – IV
I – III
40/125/21
2
1230
2306
Unit
VPEAK
VPEAK
1968
8000
VPEAK
VPEAK
TS
PS,INPUT
PS,OUTPUT
RS
175
400
1200
> 109
°C
mW
mW
Ohm
Notes:
Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Surface mount classification is class A in accordance with CECCOO802.
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulation section IEC/EN/DIN
EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test profiles.
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Symbol
L(101)
L(102)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
Value
8.3
8.3
0.5
>175
IIIa
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110)
4