English
Language : 

HFBR-0508 Datasheet, PDF (2/8 Pages) AVAGO TECHNOLOGIES LIMITED – 10 Megabaud Versatile Link Fiber Optic Transmitter and Receiver for 1 mm POF and 200 μm HCS®
HFBR-0508 Series 10 MBd Data Link
Typical Link Performance, TA = +25°C
         Parameter
Symbol
Signaling Rate
fS
Link Distance with Extra Low Loss POF Cable
Link Distance with 200 µm HCS Cable
Typ.[1]
15
100
900
Unit Condition
Mb/s   NRZ
m   10 MBd
m   10 MBd
Specified Link Performance, TA = -40° to +85°C, DC to 10 MBd, unless otherwise noted.
     Parameter
Symbol
Min. Max. Unit    Condition
Signaling Rate
fS
Link Distance with Extra Low
DC
10 Mb/s NRZ
0.1
50
m +25°C
Loss POF Cable
0.1
40 0 to +70°C
0.1
30 -40 to +85°C
Link Distance with 200 µm
HCS Cable
0.1
500
m +25°C
0.1
300 0 to +70°C
0.1
100 -40 to +85°C
Pulse Width Distortion
PWD
-30
+30
ns 25 – 75% Duty Cycle
-50
+50
ns Arbitrary Duty Cycle
Note
2
2, 3, 5
2, 4, 5
Note
2
2, 3, 5
2, 4, 5
2
Absolute Maximum Ratings
          Parameter
Symbol
Min.
Storage and Operating Temperature
TS,O
- 40
Receiver Supply Voltage
VCC
- 0.5
Receiver Average Output Current
IO,AVG
-16
Receiver Output Power Dissipation
POD
Transmitter Peak Forward Input Current
IF,PK
Transmitter Average Forward Input Current
IF,AVG
Transmitter Reverse Input Voltage
VR
Lead Soldering Cycle           Temp
TSOL
                     Time
Max.
+85
+5.5
+16
80
90
60
3
+260
10
Unit
Note
°C
V
mA
mW
mA
6
mA
V
°C
7
sec
7
Recommended Operating Conditions
       Parameter
Ambient Temperature
Power Supply Voltage
Transmitter Peak Forward Current
Transmitter Average Forward Current
Fanout (7400 Series TTL)
Symbol Min. Max. Unit   Condition
Note
TA
-40 +85
°C
VCC
4.75 5.25
V
<100 mVp-p Noise
IF,PK
20
90
mA
6
IF,AV
60
mA
N
1
Notes:
1. Typical data at +25°C, VCC = 5 V.
2. With recommended transmitter and receiver application circuits (60 mA nominal drive current).
3. POF is HFBR-R/EXXYYY plastic (1 mm) optical fiber. Worst case attenuation used (0.23 dB/m from -40°C to +85°C at 660 nm).
4. HCS is HFBR-H/VXXYYY hard clad silica (200/230 µm) fiber. Worst case attenuation is used (10 dB/km from 0°C to +70°C and 12 dB/km from
-40°C to +85°C at 650 nm).
5. BER ≤ 10-9, 223 - 1 PRBS NRZ 10 MBd.
6. For IF,PK > 60 mA, the duty factor must maintain IF,AV ≤ 60 mA and pulse with ≤ 1 µs.
7. 1.6 mm below seating plane.