Package Characteristics
Parameter
Sym. Min. Typ.** Max. Units Test Conditions
Fig. Note
Input-Output Momentary
VISO
3750
Withstand Voltage†
V rms RH < 50%, t = 1 min.,
3, 8
TA = 25°C
Option 020
5000
3, 9
HCNW139
HCNW138
Resistance (Input-Output)
RI-O
1012

VI-O = 500 Vdc
3
RH < 45%
Capacitance (Input-Output) CI-O
0.6
pF
f = 1 MHz
3
**All typicals at T = 25°C, unless otherwise noted.
A
†The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating.
For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level safety
specification or Avago Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage.”
Notes:
1. DC CURRENT TRANSFER RATIO (CTR) is defined as the ratio of output collector current, IO, to the forward LED input current, IF, times 100%.
2. Pin 7 Open.
3. Device considered a two-terminal device. Pins 1, 2, 3, and 4 shorted together and Pins 5, 6, 7, and 8 shorted together.
4. Use of a resistor between pin 5 and 7 will decrease gain and delay time. Significant reduction in overall gain can occur when using resistor values
below 47 k. For more information, please contact your local Avago Components representative.
5. Common mode transient immunity in a Logic High level is the maximum tolerable (positive) dVCM/dt of the common mode pulse, VCM, to assure
that the output will remain in a Logic High state (i.e., VO > 2.0 V). Common mode transient immunity in a Logic Low level is the maximum tolerable
(negative) dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in a Logic Low state (i.e., VO < 0.8 V).
6. In applications where dV/dt may exceed 50,000 V/μs (such as static discharge) a series resistor, RCC, should be included to protect the
detector IC from destructively high surge currents. The recommended value is RCC = 220 .
7. Use of a 0.1 F bypass capacitor connected between pins 8 and 5 adjacent to the device is recommended.
8. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage 4500 V rms for 1 second (leakage detection
current limit, II-O < 5 A). This test is performed before the 100% production test shown in the IEC/EN/DIN EN 60747-5-2 Insulation Related Char-
acteristics Table, if applicable.
9. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage > 6000 V rms for 1 second (leakage detection
current limit, II-O < 5 A). This test is performed before the 100% production test for partial discharge (method b) shown in the IEC/EN/DIN EN
60747-5-2 Insulation Related Characteristics Table, if applicable.
12