English
Language : 

HCNW138-300E Datasheet, PDF (11/14 Pages) –
Switching Specifications (AC)
Over recommended operating conditions (TA = 0 to 70°C), VCC = 5 V, unless otherwise specified.
Parameter
Sym. Device Min. Typ.**
Max.
Units Test Conditions
Propagation
Delay Time
tPHL
6N139
HCPL-0701
TA =25°C
5
25*
30 s
IF = 0.5 mA,
Rl = 4.7 k
to Logic Low
at Output
HCNW139
6N139
HCPL-0701
0.2
1*
2
s
IF = 12 mA,
Rl = 270 
HCNW139
11
6N138
HCPL-0700
1.6
10*
15 s
IF = 1.6 mA,
Rl = 2.2 k
HCNW138
11
Propagation
Delay Time
tPLH
6N139
HCPL-0701
18
60*
90 s
IF = 0.5 mA,
Rl = 4.7 k
to Logic High
at Output
HCNW139
6N139
HCPL-0701
115
2
7*
10 s
IF = 12 mA,
Rl = 270 
HCNW139
11
6N138
HCPL-0700
10
35*
50 s
IF = 1.6 mA,
Rl = 2.2 k
HCNW138
70
Common Mode
Transient
Immunity at
|CMH|
1000 10000
V/s IF = 0 mA,
TA = 25°C
Rl = 2.2 k
Logic High
Output
|VCM| = 10
Vp-p
Common Mode
Transient
Immunity at
|CML|
1000 10000
V/s IF = 1.6 mA,
TA = 25°C
Rl = 2.2 k
Logic Low
Output
|VCM| = 10
Vp-p
* JEDEC Registered Data for 6N139 and 6N138.
**All typical values at TA = 25°C and VCC = 5 V, unless otherwise noted.
Fig. Note
5, 6, 2, 4
7, 9,
12
5, 6, 2, 4
7, 9,
12
13 5, 6
13 5, 6
11