Switching Specifications (AC)
Over recommended operating TA = -40°C to 85°C, IF = 5mA to 10mA, unless otherwise specified.
Parameter
Sym.
Min.
Typ.
Max. Units Conditions
Fig.
Note
Turn On Time
TON
0.25
0.5
ms
IF =5mA,
IO=120mA,
TA=25°C
11, 15
1.0
ms
IF =5mA, IO=120mA 12
Turn Off Time
TOFF
0.1
0.25
ms
0.5
ms
0.02
0.2
ms
0.5
ms
IF =10mA,
IO=120mA,
TA=25°C
IF =10mA,
IO=120mA
IF =5mA,
IO=120mA,
TA=25°C
13, 15
IF =5mA, IO=120mA 14
Output Transient
Rejection
Input-Output
Transient Rejection
dVO/dt 1
dVI-O/dt 1
0.02
0.15
ms
IF =10mA,
IO=120mA,
TA=25°C
0.2
ms
IF =10mA,
IO=120mA
7
kV/ms DVO=400V,
16
TA=25°C
≥10
kV/ms DVI-O=1000V,
17
TA=25°C
Notes:
1. For derating, refer to Figure 1, 2, 3 and 4.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should
be added in some applications to protect against over-voltage transients.
3. Threshold to switch device is IF ≥ 0.5mA, however, for qualified device performance over temperature range, it is recommended to operate at
IF =5mA.
4. Device is considered as a two terminal device:
ASSR-4110 - pin 1, 2 shorted and pin 3, 4 shorted.
ASSR-4111 - pin 1, 2, 3 shorted and pin 4, 5, 6 shorted.
ASSR-4120 and ASSR-4130 - pin 1, 2, 3, 4 shorted and pin 5, 6, 7, 8 shorted.
5. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your
equipment level safety specification, or Avago Technologies Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
6. During the pulsed R(ON) measurement ( IO duration ≤30ms), ambient (TA) and case temperature (TC) are equal.
10