[Preliminary] ATMOS -1M60/1M30
Therefore the minimum period is reduced to 1 × readout time. As the integration time is not the
same for all lines (in the following timing diagram line n integration time is greater than line 1
integration time) this mode must be used with a pulsed light source or a shutter element. More-
over any residual light when shutter output signal is inhibited must be avoided. The exposure
time is defined by the shutter time and all the lines are exposed during the same time.
See register Aperture Shutter Time @ 246H Internal Register Mapping on page 15
Table 4-3.
Label
Tsh
T1
Shutter Time Values at Triggered Mode without Full Reset
Description
1M60
1M30
Maximum shutter time (ms)
655
1310
Step duration (µs)
10
20
Figure 4-4. Triggered Mode Without Full Reset Chronogram
Trigger In
Trigger Delay
Line1 Reset
Trigger N Event
Line 1
Integration
(Frame N)
Line 1 Readout
and Reset
Line n Reset
Shutter out
FVAL
Line n
Integration
(Frame N)
Line n Readout
and Reset
Frame N
Readout
Programmable
Shutter Time
4.1.5
ITC Mode
Principle: An external sync controls both the integration time and the frame rate.
The trigger event initiates the following sequence:
• Stop of readout frame in progress and reset of readout pointer to line 1
• Shutter output signal is activated during a time defined by the high state of the ITC signal
• Readout of frame N. The readout data is forwarded to the CameraLink interface (FVAL
active) starting with the first line
9