English
Language : 

1M60 Datasheet, PDF (18/26 Pages) ATMEL Corporation – CameraLink Areascan Cameras
Table 6-6.
Start Addr
(Hex)
Internal Register Mapping (Continued)
Size
Dec)
End
Addr (Hex)
Access Type
Processing Internal Task
10B
1
WO
-
10C
1
RW
-
10D
1
WO
-
10E
1
RW
-
200
2
RW
RW
202
2
RW
-
204
2
RW
-
Factory
Settings
1
1
0
0
0
Description
FPN coefficient save in dataflash
1 to 4 (1 allowed only for advanced user
mode)
FPN coefficient restore in dataflash
1 to 4
LUT coefficient save in dataflash
1 to 4 (1 allowed only for advanced user
mode)
LUT coefficient restore in dataflash
1 to 4
Calibration control
[0] = off-line calibration enabled
(0: disabled; 1: enabled)
Processing control:
[0] = offset correction enable (0: disabled;
1: enabled)
[1] = gain correction enable (0: disabled; 1:
enabled)
[2] = look-up table correction enable (0:
disabled; 1: enabled)[
[4:3] = fpn correction mode (00: disabled;
01: off-line fpn correction enabled; 11: on-
line fpn correction enabled)
Mode control:
[1:0] = test pattern (00: disabled; 01: fixed
test pattern; 10: dynamic test pattern)
[3:2] = output format (00:12-bit; 01:10-bit;
10:8-bit)
[4] = demux mode (for 1M60 then 0:
disabled; 1: enabled) (for 1M30 then 0:
disabled)
[7:5] = synchronization mode (000: Free-
run; 001: External triggered; 010: external
triggered without full reset; 011: integration
time controlled); others reserved
[8] = trigger source (0: CameraLink; 1:
external)
[9] = trigger polarity (0:positive edge; 1:
negative edge)
[10] = shutter polarity output (0: positive
edge; 1: negative edge)
206
1
WO
Software reset:
1 = camera reset
18 ATMOS -1M60/1M30 [Preliminary]
5429B–IMAGE–04/05