Figure 10-5. Brown-out Reset During Operation
VCC
VBOT-
RESET
VBOT+
TIME-OUT
tTOUT
10.2.4
Watchdog Reset
INTERNAL
RESET
When the Watchdog times out, it will generate a short reset pulse of one CK cycle duration. On
the falling edge of this pulse, the delay timer starts counting the Time-out period tTOUT. Refer to
page 49 for details on operation of the Watchdog Timer.
Figure 10-6. Watchdog Reset During Operation
CC
CK
10.3 Internal Voltage Reference
10.3.1
ATmega325P/3250P features an internal bandgap reference. This reference is used for Brown-
out Detection, and it can be used as an input to the Analog Comparator or the ADC.
Voltage Reference Enable Signals and Start-up Time
The voltage reference has a start-up time that may influence the way it should be used. The
start-up time is given in ”System and Reset Characterizations” on page 308. To save power, the
reference is not always turned on. The reference is on during the following situations:
1. When the BOD is enabled (by programming the BODLEVEL [1:0] Fuse).
2. When the bandgap reference is connected to the Analog Comparator (by setting the
ACBG bit in ACSR).
3. When the ADC is enabled.
Thus, when the BOD is not enabled, after setting the ACBG bit or enabling the ADC, the user
must always allow the reference to start up before the output from the Analog Comparator or
48 ATmega325P/3250P